User name adev
Log entry time 04:14:53 on April 14, 2001
Entry number 60430
keyword=End_of_Run_3543
****************************
Run Number: 3543
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51 ,mode=coincidence,Lmom=0.5267,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
Time of run = 15.772461 min
Av. current (on 3x) = 48.265349 uA
Av. current (on 1x) = 48.117834 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 45.5362 | 45.6758 | 45.7092
up-down (mC)| -0.3616 | -0.1557 | -0.1228
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 113548.61 Hz | 2352590.9 /mC | 11.355 Hz | 107456470 | 10000 | 2359803.2 /mC
2 | 51105.022 Hz | 1058834.6 /mC | 10.221 Hz | 48363118 | 5000 | 1062080.7 /mC
3 | 111979.18 Hz | 2320073.9 /mC | 11.198 Hz | 105971230 | 10000 | 2327186.5 /mC
4 | 42896.777 Hz | 888769.7 /mC | 10.724 Hz | 40595265 | 4000 | 891494.3 /mC
5 | 1205.3446 Hz | 24973.3 /mC | 1205.345 Hz | 1140675 | 1 | 25049.8 /mC
Trigger 5 corrected for pulser:
5 (phys) | 1195.1729 Hz | 24762.5 /mC | 1195.173 Hz | 1131049.0 | 1 | 24838.5 /mC
8 | 1024.0 Hz | 21216.0 /mC | 0.016 Hz | 969060 | 65535 | 21281.1 /mC
output 1058.701 Hz
Av. deadtime from accepted triggers = 0.1521
Av. deadtime from gated scalers = 0.1509
Accepted triggers = 1001899.00000
Rate of Left Arm Pulser for electronic DT = 10.171738
Rate of Right Arm Pulser for electronic DT = 10.198155
Rate of Left Arm Pulser&trig for electronic DT = 10.101996
Rate of Right Arm Pulser&trig for electronic DT = 10.194985
Left Arm Electronic DT = 0.0068564305
Right Arm Electronic DT = 0.00031084862
Rate of Left Strobe = 244215.79
Rate of Right Arm Strobe = 203729.56
Signal | Charge (C)
upstream | 0.0453554
upstream 3x | 0.0455979
upstream 10x| 0.0456478
downstream | 0.0457170
downstream 3x | 0.0457536
downstream 10x| 0.0457706
****************************
End-of-run EPICS data for Run Number 3543 at Sat Apr 14 04:14:42 EDT 2001
Right Arm D1 momentum : 1.04
Right Arm arm angle : 19.0134
Left Arm D1 momentum : 0.52669
Left Arm arm angle : 41.5622
Tiefenbach Hall A energy : 1722.69
Right Arm arm mispointing (HPT) : -1.73504
Left Arm arm mispointing (HPT) : 5.65833
Right Arm Q1 power supply current : 781.9
Right Arm Q1 momentum : 1.03985
Right Arm Q1 gauss meter : -0.019556
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.383
Right Arm Q2 momentum : 1.03954
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 413.712
Right Arm Q3 momentum : 1.03972
Right Arm Q3 gauss meter : 0.18542
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.2
Left Arm Q1 momentum : 0.52663
Left Arm Q1 gauss meter : 0.03426
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.561
Left Arm Q2 momentum : 0.526152
Left Arm Q2 gauss meter : -0.12005
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.112
Left Arm D1 momentum : 0.52669
Left Arm D1 NMR : 0.195115
Left Arm Q3 power supply current : 209.625
Left Arm Q3 momentum : 0.526539
Left Arm Q3 gauss meter : 0.10559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.6754
Current on Unser monitor : 56.1151
Current on Upstream bcm : 48.8059
Current on Downstream bcm : 48.5449
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 97.6398
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 1722.69
Tiefenbach Hall C energy : 884.006
Delta(E)/E width (MV_AI_DXWID) : 0.203983
IPM1C12.XPOS : -0.00175384
IPM1H04A.XPOS : 0.743274
IPM1H04A.YPOS : 0.817324
IPM1H04B.XPOS : -0.0479193
IPM1H04B.YPOS : -0.0094171
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -942
HacR_VPM_LVDT:VALr : 72
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.818359
HacR_alignROLL : -0.337207
HacR_alignPITCH : -0.0336042
HacR_alignHPT : -1.73361
HacL_HPM_LVDT:VALr : -8452
HacL_VPM_LVDT:VALr : -465
HacL_HPE1313A:0_Ch58 : -0.234863
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.25
HacL_alignROLL : 0.111799
HacL_alignPITCH : -0.0351535
HacL_alignHPT : 5.65721
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.26
haH2_P_Exhaust_R : 20.53
haH2_P_Fill_Bottle_R : 20.24
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.43
haD2_P_Fill_Bottle_R : 38.07
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 242.18
haSC200_6_Sensor_2_R : 26.48
haSC200_6_Sensor_3_R : 42.67
haSC200_6_Sensor_4_R : 41.76
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.58
haITC502_1_Sensor_3_R : 80.92
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.12
haITC502_4_Sensor_1_R : 87.4
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 95.91
haITC502_5_Sensor_2_R : 93.61
haITC502_5_Sensor_3_R : 266.6
haITC502_6_Sensor_1_R : 99.92
haITC502_6_Sensor_2_R : 85.35
haITC502_6_Sensor_3_R : 28.76
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.616992
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 247
Laser power Hall A : 57
Half-wave plate (off=out) : ON