• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 04:14:53 on April 14, 2001

    Entry number 60430

    keyword=End_of_Run_3543
    ****************************
     Run Number: 3543
    End of Run Comment:
    RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51 ,mode=coincidence,Lmom=0.5267,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
    
    
    Time of run = 15.772461 min
    Av. current (on 3x) = 48.265349 uA
    Av. current (on 1x) = 48.117834 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   45.5362  |   45.6758  |   45.7092
    up-down    (mC)|   -0.3616  |   -0.1557  |   -0.1228
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 113548.61 Hz  |   2352590.9 /mC  |   11.355 Hz  | 107456470  | 10000   |   2359803.2 /mC
        2      | 51105.022 Hz  |   1058834.6 /mC  |   10.221 Hz  |  48363118  |  5000   |   1062080.7 /mC
        3      | 111979.18 Hz  |   2320073.9 /mC  |   11.198 Hz  | 105971230  | 10000   |   2327186.5 /mC
        4      | 42896.777 Hz  |    888769.7 /mC  |   10.724 Hz  |  40595265  |  4000   |    891494.3 /mC
        5      | 1205.3446 Hz  |     24973.3 /mC  | 1205.345 Hz  |   1140675  |     1   |     25049.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1195.1729 Hz  |     24762.5 /mC  | 1195.173 Hz  | 1131049.0  |     1   |     24838.5 /mC
        8    | 1024.0 Hz  |     21216.0 /mC  |    0.016 Hz  |    969060  | 65535   |     21281.1 /mC
        output                      1058.701 Hz
    Av. deadtime from accepted triggers = 0.1521
    Av. deadtime from gated scalers = 0.1509
    Accepted triggers  = 1001899.00000
    Rate of Left Arm Pulser for electronic DT  = 10.171738
    Rate of Right Arm Pulser for electronic DT  = 10.198155
    Rate of Left Arm Pulser&trig for electronic DT  = 10.101996
    Rate of Right Arm Pulser&trig for electronic DT  = 10.194985
    Left Arm Electronic DT  = 0.0068564305
    Right Arm Electronic DT  = 0.00031084862
    Rate of Left Strobe  = 244215.79
    Rate of Right Arm Strobe  = 203729.56
        Signal     |    Charge   (C)   
       upstream    |    0.0453554     
       upstream 3x |    0.0455979     
       upstream 10x|    0.0456478     
      downstream   |    0.0457170   
     downstream 3x |    0.0457536   
     downstream 10x|    0.0457706    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3543 at Sat Apr 14 04:14:42 EDT 2001
    Right Arm D1 momentum                    : 1.04
    Right Arm arm angle                      : 19.0134
    Left Arm D1 momentum                      : 0.52669
    Left Arm arm angle                        : 41.5622
    Tiefenbach Hall A energy                : 1722.69
    Right Arm arm mispointing (HPT)          : -1.73504
    Left Arm arm mispointing (HPT)            : 5.65833
    Right Arm Q1 power supply current        : 781.9
    Right Arm Q1 momentum                    : 1.03985
    Right Arm Q1 gauss meter                 : -0.019556
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 447.383
    Right Arm Q2 momentum                    : 1.03954
    Right Arm Q2 gauss meter                 : 0.2352
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 355
    Right Arm D1 momentum                    : 1.04
    Right Arm D1 NMR                         : 0.385931
    Right Arm Q3 power supply current        : 413.712
    Right Arm Q3 momentum                    : 1.03972
    Right Arm Q3 gauss meter                 : 0.18542
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 396.2
    Left Arm Q1 momentum                      : 0.52663
    Left Arm Q1 gauss meter                   : 0.03426
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 226.561
    Left Arm Q2 momentum                      : 0.526152
    Left Arm Q2 gauss meter                   : -0.12005
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 175.112
    Left Arm D1 momentum                      : 0.52669
    Left Arm D1 NMR                           : 0.195115
    Left Arm Q3 power supply current          : 209.625
    Left Arm Q3 momentum                      : 0.526539
    Left Arm Q3 gauss meter                   : 0.10559
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 48.6754
    Current on Unser monitor                : 56.1151
    Current on Upstream bcm                 : 48.8059
    Current on Downstream bcm               : 48.5449
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 97.6398
    MBSY1c Hall A Beam energy               : 1724.44
    MBSY1c magnet current (amp)             : 71.6882
    MBSY1c Bdl                              : 430337
    MBSY3c Hall C Beam energy               : 885.654
    Tiefenbach Hall A energy                : 1722.69
    Tiefenbach Hall C energy                : 884.006
    Delta(E)/E width (MV_AI_DXWID)          : 0.203983
    IPM1C12.XPOS                            : -0.00175384
    IPM1H04A.XPOS                           : 0.743274
    IPM1H04A.YPOS                           : 0.817324
    IPM1H04B.XPOS                           : -0.0479193
    IPM1H04B.YPOS                           : -0.0094171
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -942
     HacR_VPM_LVDT:VALr                     : 72
     HacR_HPE1313A:0_Ch58                   : -0.521484
     HacR_HPE1313A:0_Ch55                   : 23.0469
     HacR_HPE1313A:0_Ch54                   : -0.818359
     HacR_alignROLL                         : -0.337207
     HacR_alignPITCH                        : -0.0336042
     HacR_alignHPT                          : -1.73361
     HacL_HPM_LVDT:VALr                     : -8452
     HacL_VPM_LVDT:VALr                     : -465
     HacL_HPE1313A:0_Ch58                   : -0.234863
     HacL_HPE1313A:0_Ch55                   : 23.7793
     HacL_HPE1313A:0_Ch54                   : -0.25
     HacL_alignROLL                         : 0.111799
     HacL_alignPITCH                        : -0.0351535
     HacL_alignHPT                          : 5.65721
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 65.5
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 20.26
    haH2_P_Exhaust_R                         : 20.53
    haH2_P_Fill_Bottle_R                     : 20.24
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.43
    haD2_P_Fill_Bottle_R                     : 38.07
    haD2_DP_Fill_Exhaust_R                   : 0.0746
    haSC200_6_Sensor_1_R                     : 242.18
    haSC200_6_Sensor_2_R                     : 26.48
    haSC200_6_Sensor_3_R                     : 42.67
    haSC200_6_Sensor_4_R                     : 41.76
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.58
    haITC502_1_Sensor_3_R                    : 80.92
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.12
    haITC502_4_Sensor_1_R                    : 87.4
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 95.91
    haITC502_5_Sensor_2_R                    : 93.61
    haITC502_5_Sensor_3_R                    : 266.6
    haITC502_6_Sensor_1_R                    : 99.92
    haITC502_6_Sensor_2_R                    : 85.35
    haITC502_6_Sensor_3_R                    : 28.76
    Right Arm Arm Collimator                 : 0.615234
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 57.1655
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1290.7
    Wien field                               : 37.497
    Laser attenuation Hall A                 : 247
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON