User name adev
Log entry time 04:44:11 on April 14, 2001
Entry number 60433
keyword=End_of_Run_3544
****************************
Run Number: 3544
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51 ,mode=coincidence,Lmom=0.5267,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
Time of run = 28.358658 min
Av. current (on 3x) = 33.885007 uA
Av. current (on 1x) = 33.770991 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 57.4620 | 57.6560 | 57.7456
up-down (mC)| -0.4326 | -0.2196 | -0.1467
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 80673.591 Hz | 2380804.9 /mC | 8.067 Hz | 137267690 | 10000 | 2388842.9 /mC
2 | 36913.831 Hz | 1089385.4 /mC | 7.383 Hz | 62809603 | 5000 | 1093063.3 /mC
3 | 79236.458 Hz | 2338392.9 /mC | 7.924 Hz | 134822380 | 10000 | 2346287.6 /mC
4 | 31087.069 Hz | 917428.4 /mC | 7.772 Hz | 52895254 | 4000 | 920525.8 /mC
5 | 611.98123 Hz | 18060.5 /mC | 611.981 Hz | 1041298 | 1 | 18121.5 /mC
Trigger 5 corrected for pulser:
5 (phys) | 601.8115 Hz | 17760.4 /mC | 601.812 Hz | 1023994.0 | 1 | 17820.4 /mC
8 | 1024.0 Hz | 30219.9 /mC | 0.016 Hz | 1742356 | 65535 | 30321.9 /mC
output 589.212 Hz
Av. deadtime from accepted triggers = 0.0837
Av. deadtime from gated scalers = 0.0832
Accepted triggers = 1002555.00000
Rate of Left Arm Pulser for electronic DT = 10.169734
Rate of Right Arm Pulser for electronic DT = 10.179137
Rate of Left Arm Pulser&trig for electronic DT = 10.122129
Rate of Right Arm Pulser&trig for electronic DT = 10.178549
Left Arm Electronic DT = 0.0046809986
Right Arm Electronic DT = 5.7736721e-05
Rate of Left Strobe = 173695.63
Rate of Right Arm Strobe = 145091.3
Signal | Charge (C)
upstream | 0.0572457
upstream 3x | 0.0575462
upstream 10x| 0.0576723
downstream | 0.0576783
downstream 3x | 0.0577658
downstream 10x| 0.0578190
****************************
End-of-run EPICS data for Run Number 3544 at Sat Apr 14 04:43:59 EDT 2001
Right Arm D1 momentum : 1.04
Right Arm arm angle : 19.0134
Left Arm D1 momentum : 0.526691
Left Arm arm angle : 41.5622
Tiefenbach Hall A energy : 1722.71
Right Arm arm mispointing (HPT) : -1.73588
Left Arm arm mispointing (HPT) : 5.65721
Right Arm Q1 power supply current : 782.005
Right Arm Q1 momentum : 1.03999
Right Arm Q1 gauss meter : -0.019565
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.569
Right Arm Q2 momentum : 1.03997
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.002
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 413.872
Right Arm Q3 momentum : 1.04012
Right Arm Q3 gauss meter : 0.18543
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.2
Left Arm Q1 momentum : 0.52663
Left Arm Q1 gauss meter : 0.03425
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.829
Left Arm Q2 momentum : 0.526774
Left Arm Q2 gauss meter : -0.12013
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.112
Left Arm D1 momentum : 0.526692
Left Arm D1 NMR : 0.195116
Left Arm Q3 power supply current : 209.694
Left Arm Q3 momentum : 0.526713
Left Arm Q3 gauss meter : 0.1056
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 33.4193
Current on Unser monitor : 41.4264
Current on Upstream bcm : 33.3871
Current on Downstream bcm : 33.4515
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 80.4631
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 1722.7
Tiefenbach Hall C energy : 884.01
Delta(E)/E width (MV_AI_DXWID) : 0.203983
IPM1C12.XPOS : -0.000619113
IPM1H04A.XPOS : 0.741638
IPM1H04A.YPOS : 0.834451
IPM1H04B.XPOS : -0.051251
IPM1H04B.YPOS : 0.00390709
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -941
HacR_VPM_LVDT:VALr : 76
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.818359
HacR_alignROLL : -0.337149
HacR_alignPITCH : -0.0332221
HacR_alignHPT : -1.73588
HacL_HPM_LVDT:VALr : -8454
HacL_VPM_LVDT:VALr : -462
HacL_HPE1313A:0_Ch58 : -0.233887
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.25
HacL_alignROLL : 0.112241
HacL_alignPITCH : -0.0360268
HacL_alignHPT : 5.657
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64.5
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 20.19
haH2_P_Exhaust_R : 20.53
haH2_P_Fill_Bottle_R : 20.2
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.41
haD2_P_Fill_Bottle_R : 38.07
haD2_DP_Fill_Exhaust_R : 0.0745
haSC200_6_Sensor_1_R : 242.13
haSC200_6_Sensor_2_R : 26.46
haSC200_6_Sensor_3_R : 42.66
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.58
haITC502_1_Sensor_3_R : 80.33
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 19.08
haITC502_4_Sensor_1_R : 87.4
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 95.93
haITC502_5_Sensor_2_R : 93.61
haITC502_5_Sensor_3_R : 266.6
haITC502_6_Sensor_1_R : 99.95
haITC502_6_Sensor_2_R : 85.46
haITC502_6_Sensor_3_R : 28.76
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.617041
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 209
Laser power Hall A : 57
Half-wave plate (off=out) : ON