User name adev
Log entry time 06:39:37 on April 14, 2001
Entry number 60443
keyword=Start_Run_3549_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51
Beginning-of-run EPICS data for Run Number 3549 at Sat Apr 14 06:39:25 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10000,ps2=5000,ps3=10000,ps4=4000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 781.97
Right Arm Q1 momentum : 1.03994
Right Arm Q1 gauss meter : -0.019557
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.469
Right Arm Q2 momentum : 1.03974
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385932
Right Arm Q3 power supply current : 413.992
Right Arm Q3 momentum : 1.04042
Right Arm Q3 gauss meter : 0.18542
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.27
Left Arm Q1 momentum : 0.526723
Left Arm Q1 gauss meter : 0.03427
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.891
Left Arm Q2 momentum : 0.526919
Left Arm Q2 gauss meter : -0.1201
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.114
Left Arm D1 momentum : 0.526694
Left Arm D1 NMR : 0.195116
Left Arm Q3 power supply current : 209.735
Left Arm Q3 momentum : 0.526815
Left Arm Q3 gauss meter : 0.10564
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 33.5977
Current on Unser monitor : 40.7038
Current on Upstream bcm : 33.5696
Current on Downstream bcm : 33.6258
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 82.6669
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.04029
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 26.45
haSC200_6_Sensor_3_R : 42.66
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.54
haITC502_1_Sensor_3_R : 80.63
haITC502_4_Sensor_1_R : 87.4
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 95.9
haITC502_5_Sensor_3_R : 935.8
haITC502_6_Sensor_1_R : 99.91
haITC502_6_Sensor_2_R : 85.31
haITC502_6_Sensor_3_R : 28.77
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -938
HacR_VPM_LVDT:VALr : 83
HacR_HPE1313A:0_Ch58 : -0.521973
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.817871
HacR_alignROLL : -0.335669
HacR_alignPITCH : -0.0332221
HacR_alignHPT : -1.74008
HacL_HPM_LVDT:VALr : -8450
HacL_VPM_LVDT:VALr : -458
HacL_HPE1313A:0_Ch58 : -0.233887
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.249512
HacL_alignROLL : 0.112754
HacL_alignPITCH : -0.0356623
HacL_alignHPT : 5.65452
Right Arm Angle Floor Angle : 19
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 19.0134
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 48.5
Left Arm Scattering Angle : 41.5622
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 209
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88