Log entry time 08:36:22 on April 14, 2001
Entry number 60455
keyword=End_of_Run_3553
****************************
Run Number: 3553
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51 ,mode=coincidence,Lmom=0.5267,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
Time of run = 30.28195 min
Av. current (on 3x) = 32.049235 uA
Av. current (on 1x) = 31.94169 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 58.0354 | 58.2308 | 58.3231
up-down (mC)| -0.4401 | -0.2249 | -0.1519
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 76339.707 Hz | 2381951.0 /mC | 7.634 Hz | 138702910 | 10000 | 2389970.8 /mC
2 | 34923.014 Hz | 1089667.6 /mC | 6.985 Hz | 63452218 | 5000 | 1093336.4 /mC
3 | 74955.396 Hz | 2338757.7 /mC | 7.496 Hz | 136187730 | 10000 | 2346632.1 /mC
4 | 29219.071 Hz | 911693.2 /mC | 7.305 Hz | 53088626 | 4000 | 914762.8 /mC
5 | 571.23468 Hz | 17823.7 /mC | 571.235 Hz | 1037886 | 1 | 17883.7 /mC
Trigger 5 corrected for pulser:
5 (phys) | 561.06581 Hz | 17506.4 /mC | 561.066 Hz | 1019410.0 | 1 | 17565.3 /mC
8 | 1024.0 Hz | 31950.8 /mC | 0.016 Hz | 1860523 | 65535 | 32058.4 /mC
output 551.243 Hz
Av. deadtime from accepted triggers = 0.0821
Av. deadtime from gated scalers = 0.0813
Accepted triggers = 1001562.00000
Rate of Left Arm Pulser for electronic DT = 10.168874
Rate of Right Arm Pulser for electronic DT = 10.182083
Rate of Left Arm Pulser&trig for electronic DT = 10.128696
Rate of Right Arm Pulser&trig for electronic DT = 10.180432
Left Arm Electronic DT = 0.0039510717
Right Arm Electronic DT = 0.00016216216
Rate of Left Strobe = 163860.29
Rate of Right Arm Strobe = 137068.32
Signal | Charge (C)
upstream | 0.0578154
upstream 3x | 0.0581183
upstream 10x| 0.0582471
downstream | 0.0582555
downstream 3x | 0.0583432
downstream 10x| 0.0583990
****************************
End-of-run EPICS data for Run Number 3553 at Sat Apr 14 08:36:10 EDT 2001
Right Arm D1 momentum : 1.04
Right Arm arm angle : 19.0134
Left Arm D1 momentum : 0.52669
Left Arm arm angle : 41.5622
Tiefenbach Hall A energy : 1722.7
Right Arm arm mispointing (HPT) : -1.74204
Left Arm arm mispointing (HPT) : 5.65347
Right Arm Q1 power supply current : 781.97
Right Arm Q1 momentum : 1.03994
Right Arm Q1 gauss meter : -0.019567
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.66
Right Arm Q2 momentum : 1.04018
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.002
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385932
Right Arm Q3 power supply current : 413.805
Right Arm Q3 momentum : 1.03995
Right Arm Q3 gauss meter : 0.18542
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.27
Left Arm Q1 momentum : 0.526723
Left Arm Q1 gauss meter : 0.03426
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.478
Left Arm Q2 momentum : 0.525959
Left Arm Q2 gauss meter : -0.12005
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.112
Left Arm D1 momentum : 0.52669
Left Arm D1 NMR : 0.195115
Left Arm Q3 power supply current : 209.631
Left Arm Q3 momentum : 0.526555
Left Arm Q3 gauss meter : 0.10563
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 33.8118
Current on Unser monitor : 40.3615
Current on Upstream bcm : 33.7812
Current on Downstream bcm : 33.8424
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 35.5305
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 1722.7
Tiefenbach Hall C energy : 884.204
Delta(E)/E width (MV_AI_DXWID) : 0.203983
IPM1C12.XPOS : 0.0041365
IPM1H04A.XPOS : 0.758732
IPM1H04A.YPOS : 0.844885
IPM1H04B.XPOS : -0.0223999
IPM1H04B.YPOS : 0.0341768
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -936
HacR_VPM_LVDT:VALr : 88
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.817383
HacR_alignROLL : -0.336104
HacR_alignPITCH : -0.0341868
HacR_alignHPT : -1.74207
HacL_HPM_LVDT:VALr : -8449
HacL_VPM_LVDT:VALr : -455
HacL_HPE1313A:0_Ch58 : -0.233887
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.249023
HacL_alignROLL : 0.11254
HacL_alignPITCH : -0.0359547
HacL_alignHPT : 5.65368
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.37
haH2_P_Exhaust_R : 20.69
haH2_P_Fill_Bottle_R : 20.39
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.52
haD2_P_Fill_Bottle_R : 38.26
haD2_DP_Fill_Exhaust_R : 0.0745
haSC200_6_Sensor_1_R : 242.08
haSC200_6_Sensor_2_R : 26.41
haSC200_6_Sensor_3_R : 42.67
haSC200_6_Sensor_4_R : 41.72
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.45
haITC502_1_Sensor_3_R : 80.44
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.08
haITC502_4_Sensor_1_R : 87.1
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 313.43
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.7
haITC502_6_Sensor_2_R : 85.12
haITC502_6_Sensor_3_R : 28.76
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 212
Laser power Hall A : 57
Half-wave plate (off=out) : ON