User name adev
Log entry time 12:16:51 on April 14, 2001
Entry number 60469
keyword=End_of_Run_3560
****************************
Run Number: 3560
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51 ,mode=coincidence,Lmom=0.5267,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
Time of run = 29.545297 min
Av. current (on 3x) = 32.836755 uA
Av. current (on 1x) = 32.727657 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 58.0169 | 58.2103 | 58.3026
up-down (mC)| -0.4440 | -0.2223 | -0.1524
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 78264.785 Hz | 2383450.7 /mC | 7.826 Hz | 138741380 | 10000 | 2391396.0 /mC
2 | 35717.27 Hz | 1087722.3 /mC | 7.143 Hz | 63316641 | 5000 | 1091348.2 /mC
3 | 76835.955 Hz | 2339937.4 /mC | 7.684 Hz | 136208460 | 10000 | 2347737.6 /mC
4 | 29881.14 Hz | 909990.6 /mC | 7.470 Hz | 52970828 | 4000 | 913024.1 /mC
5 | 585.68882 Hz | 17836.4 /mC | 585.689 Hz | 1038261 | 1 | 17895.8 /mC
Trigger 5 corrected for pulser:
5 (phys) | 575.51743 Hz | 17526.6 /mC | 575.517 Hz | 1020230.0 | 1 | 17585.0 /mC
8 | 1024.0 Hz | 31184.6 /mC | 0.016 Hz | 1815263 | 65535 | 31288.5 /mC
output 565.149 Hz
Av. deadtime from accepted triggers = 0.0821
Av. deadtime from gated scalers = 0.0812
Accepted triggers = 1001849.00000
Rate of Left Arm Pulser for electronic DT = 10.171388
Rate of Right Arm Pulser for electronic DT = 10.180977
Rate of Left Arm Pulser&trig for electronic DT = 10.117234
Rate of Right Arm Pulser&trig for electronic DT = 10.180977
Left Arm Electronic DT = 0.0053241639
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 167932.62
Rate of Right Arm Strobe = 140178.26
Signal | Charge (C)
upstream | 0.0577949
upstream 3x | 0.0580991
upstream 10x| 0.0582264
downstream | 0.0582389
downstream 3x | 0.0583214
downstream 10x| 0.0583788
****************************
End-of-run EPICS data for Run Number 3560 at Sat Apr 14 12:16:37 EDT 2001
Right Arm D1 momentum : 1.04
Right Arm arm angle : 19.0134
Left Arm D1 momentum : 0.526691
Left Arm arm angle : 41.5623
Tiefenbach Hall A energy : 1722.71
Right Arm arm mispointing (HPT) : -1.74564
Left Arm arm mispointing (HPT) : 5.64789
Right Arm Q1 power supply current : 782.075
Right Arm Q1 momentum : 1.04008
Right Arm Q1 gauss meter : -0.019574
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.689
Right Arm Q2 momentum : 1.04025
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.001
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 413.942
Right Arm Q3 momentum : 1.04029
Right Arm Q3 gauss meter : 0.18546
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.27
Left Arm Q1 momentum : 0.526723
Left Arm Q1 gauss meter : 0.03426
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.981
Left Arm Q2 momentum : 0.527128
Left Arm Q2 gauss meter : -0.12017
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.111
Left Arm D1 momentum : 0.526691
Left Arm D1 NMR : 0.195116
Left Arm Q3 power supply current : 209.651
Left Arm Q3 momentum : 0.526603
Left Arm Q3 gauss meter : 0.1056
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 33.333
Current on Unser monitor : 40.4174
Current on Upstream bcm : 33.2742
Current on Downstream bcm : 33.3919
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 82.0213
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 1722.7
Tiefenbach Hall C energy : 884.006
Delta(E)/E width (MV_AI_DXWID) : 0.20371
IPM1C12.XPOS : -0.00568287
IPM1H04A.XPOS : 0.760495
IPM1H04A.YPOS : 0.861349
IPM1H04B.XPOS : -0.0129528
IPM1H04B.YPOS : 0.0527125
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -933
HacR_VPM_LVDT:VALr : 91
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.817383
HacR_alignROLL : -0.336221
HacR_alignPITCH : -0.0331553
HacR_alignHPT : -1.74648
HacL_HPM_LVDT:VALr : -8442
HacL_VPM_LVDT:VALr : -459
HacL_HPE1313A:0_Ch58 : -0.233398
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.248047
HacL_alignROLL : 0.112683
HacL_alignPITCH : -0.0364635
HacL_alignHPT : 5.64673
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 68
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 21.66
haH2_P_Exhaust_R : 22.01
haH2_P_Fill_Bottle_R : 21.67
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 19.56
haD2_P_Fill_Bottle_R : 40.36
haD2_DP_Fill_Exhaust_R : 0.0744
haSC200_6_Sensor_1_R : 242.2
haSC200_6_Sensor_2_R : 26.38
haSC200_6_Sensor_3_R : 42.77
haSC200_6_Sensor_4_R : 41.76
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.32
haITC502_1_Sensor_3_R : 80.24
haITC502_2_Sensor_1_R : 18.99
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 19.08
haITC502_4_Sensor_1_R : 87
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 95.59
haITC502_5_Sensor_2_R : 93.33
haITC502_5_Sensor_3_R : 266.4
haITC502_6_Sensor_1_R : 99.53
haITC502_6_Sensor_2_R : 84.88
haITC502_6_Sensor_3_R : 28.75
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 209
Laser power Hall A : 57
Half-wave plate (off=out) : ON