User name adev
Log entry time 12:51:26 on April 14, 2001
Entry number 60472
keyword=Start_Run_3562_RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51
Beginning-of-run EPICS data for Run Number 3562 at Sat Apr 14 12:51:15 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10000,ps2=5000,ps3=10000,ps4=4000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 782.075
Right Arm Q1 momentum : 1.04008
Right Arm Q1 gauss meter : -0.019572
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.361
Right Arm Q2 momentum : 1.03949
Right Arm Q2 gauss meter : 0.2352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.001
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 413.796
Right Arm Q3 momentum : 1.03993
Right Arm Q3 gauss meter : 0.18544
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.305
Left Arm Q1 momentum : 0.526769
Left Arm Q1 gauss meter : 0.03427
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.54
Left Arm Q2 momentum : 0.526103
Left Arm Q2 gauss meter : -0.12006
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.113
Left Arm D1 momentum : 0.52669
Left Arm D1 NMR : 0.195115
Left Arm Q3 power supply current : 209.594
Left Arm Q3 momentum : 0.526461
Left Arm Q3 gauss meter : 0.1056
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 33.4023
Current on Unser monitor : 40.4187
Current on Upstream bcm : 33.4851
Current on Downstream bcm : 33.3353
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 81.7414
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.15873
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.15
haSC200_6_Sensor_2_R : 26.41
haSC200_6_Sensor_3_R : 42.77
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.32
haITC502_1_Sensor_3_R : 80.42
haITC502_4_Sensor_1_R : 87
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 3.99
haITC502_5_Sensor_3_R : 10
haITC502_6_Sensor_1_R : 99.52
haITC502_6_Sensor_2_R : 85.01
haITC502_6_Sensor_3_R : 28.75
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -933
HacR_VPM_LVDT:VALr : 93
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.816406
HacR_alignROLL : -0.335727
HacR_alignPITCH : -0.0336042
HacR_alignHPT : -1.74452
HacL_HPM_LVDT:VALr : -8443
HacL_VPM_LVDT:VALr : -459
HacL_HPE1313A:0_Ch58 : -0.233887
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.248047
HacL_alignROLL : 0.113937
HacL_alignPITCH : -0.0359547
HacL_alignHPT : 5.64613
Right Arm Angle Floor Angle : 19
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 19.0134
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 48.5
Left Arm Scattering Angle : 41.5623
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 211
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88