Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 12:53:10 on April 14, 2001
Entry number 60473
keyword=End_of_Run_3562
****************************
Run Number: 3562
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin51 ,mode=coincidence,Lmom=0.5267,Rmom=-1.040,Ene=1.721,Angle_R=19.013,Angle_L=41.562
Time of run = 1.5997396 min
Av. current (on 3x) = 33.390851 uA
Av. current (on 1x) = 33.280417 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 3.1944 | 3.2050 | 3.2102
up-down (mC)| -0.0244 | -0.0121 | -0.0083
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 79896.66 Hz | 2392771.0 /mC | 7.990 Hz | 7668831 | 10000 | 2400710.9 /mC
2 | 36810.022 Hz | 1102398.4 /mC | 7.362 Hz | 3533187 | 5000 | 1106056.5 /mC
3 | 76677.949 Hz | 2296376.0 /mC | 7.668 Hz | 7359885 | 10000 | 2303996.1 /mC
4 | 30474.877 Hz | 912671.4 /mC | 7.619 Hz | 2925112 | 4000 | 915700.0 /mC
5 | 585.40778 Hz | 17532.0 /mC | 585.408 Hz | 56190 | 1 | 17590.2 /mC
Trigger 5 corrected for pulser:
5 (phys) | 575.24988 Hz | 17227.8 /mC | 575.250 Hz | 55215.0 | 1 | 17284.9 /mC
8 | 1024.0 Hz | 30667.1 /mC | 0.016 Hz | 98288 | 65535 | 30768.8 /mC
output 565.675 Hz
Av. deadtime from accepted triggers = 0.0816
Av. deadtime from gated scalers = 0.0799
Accepted triggers = 54296.00000
Rate of Left Arm Pulser for electronic DT = 10.157903
Rate of Right Arm Pulser for electronic DT = 10.366271
Rate of Left Arm Pulser&trig for electronic DT = 10.05372
Rate of Right Arm Pulser&trig for electronic DT = 10.355852
Left Arm Electronic DT = 0.01025641
Right Arm Electronic DT = 0.0010050251
Rate of Left Strobe = 168936.34
Rate of Right Arm Strobe = 142556.92
Signal | Charge (C)
upstream | 0.0031822
upstream 3x | 0.0031990
upstream 10x| 0.0032060
downstream | 0.0032066
downstream 3x | 0.0032111
downstream 10x| 0.0032143
****************************
End-of-run EPICS data for Run Number 3562 at Sat Apr 14 12:52:55 EDT 2001
Right Arm D1 momentum : 1.04
Right Arm arm angle : 19.0134
Left Arm D1 momentum : 0.526691
Left Arm arm angle : 41.5623
Tiefenbach Hall A energy : 1722.85
Right Arm arm mispointing (HPT) : -1.74505
Left Arm arm mispointing (HPT) : 5.64743
Right Arm Q1 power supply current : 781.97
Right Arm Q1 momentum : 1.03994
Right Arm Q1 gauss meter : -0.019559
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 447.645
Right Arm Q2 momentum : 1.04015
Right Arm Q2 gauss meter : 0.2353
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 355.001
Right Arm D1 momentum : 1.04
Right Arm D1 NMR : 0.385931
Right Arm Q3 power supply current : 414.061
Right Arm Q3 momentum : 1.04059
Right Arm Q3 gauss meter : 0.18546
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 396.305
Left Arm Q1 momentum : 0.526769
Left Arm Q1 gauss meter : 0.03428
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 226.602
Left Arm Q2 momentum : 0.526248
Left Arm Q2 gauss meter : -0.12008
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 175.113
Left Arm D1 momentum : 0.526691
Left Arm D1 NMR : 0.195115
Left Arm Q3 power supply current : 209.694
Left Arm Q3 momentum : 0.526712
Left Arm Q3 gauss meter : 0.10559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 33.5236
Current on Unser monitor : 40.7078
Current on Upstream bcm : 33.6519
Current on Downstream bcm : 33.3953
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 81.9006
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 1722.84
Tiefenbach Hall C energy : 884
Delta(E)/E width (MV_AI_DXWID) : 0.20371
IPM1C12.XPOS : -0.00301626
IPM1H04A.XPOS : 1.09292
IPM1H04A.YPOS : -0.328341
IPM1H04B.XPOS : 1.20997
IPM1H04B.YPOS : -1.52501
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -933
HacR_VPM_LVDT:VALr : 93
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.817383
HacR_alignROLL : -0.336163
HacR_alignPITCH : -0.0332221
HacR_alignHPT : -1.7454
HacL_HPM_LVDT:VALr : -8446
HacL_VPM_LVDT:VALr : -460
HacL_HPE1313A:0_Ch58 : -0.233398
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.248047
HacL_alignROLL : 0.113124
HacL_alignPITCH : -0.0364635
HacL_alignHPT : 5.64987
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 21.74
haH2_P_Exhaust_R : 22.05
haH2_P_Fill_Bottle_R : 21.73
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 19.54
haD2_P_Fill_Bottle_R : 40.36
haD2_DP_Fill_Exhaust_R : 0.0744
haSC200_6_Sensor_1_R : 242.18
haSC200_6_Sensor_2_R : 26.4
haSC200_6_Sensor_3_R : 42.76
haSC200_6_Sensor_4_R : 41.77
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.31
haITC502_1_Sensor_3_R : 80.07
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.08
haITC502_4_Sensor_1_R : 87
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.64
haITC502_5_Sensor_2_R : 312.95
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.52
haITC502_6_Sensor_2_R : 84.88
haITC502_6_Sensor_3_R : 28.75
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.617041
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 212
Laser power Hall A : 57
Half-wave plate (off=out) : ON