Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 18:40:56 on April 14, 2001
Entry number 60510
keyword=Start_Run_3578_RunType=Other,Tar=LD2-15cm,Rad=out,comment=triple
Beginning-of-run EPICS data for Run Number 3578 at Sat Apr 14 18:40:36 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=5,ps2=5000,ps3=65535,ps4=65535,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1566.29
Right Arm Q1 momentum : 2.08301
Right Arm Q1 gauss meter : -0.03896
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 896.289
Right Arm Q2 momentum : 2.08261
Right Arm Q2 gauss meter : 0.471
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 725.699
Right Arm D1 momentum : 2.083
Right Arm D1 NMR : 0.772976
Right Arm Q3 power supply current : 828.906
Right Arm Q3 momentum : 2.08316
Right Arm Q3 gauss meter : 0.3719
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0005201
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.223072
Left Arm Q2 momentum : 0.00051805
Left Arm Q2 gauss meter : -0.0008328
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1.10506
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.161337
Left Arm Q3 power supply current : 1.9434
Left Arm Q3 momentum : 0.00488146
Left Arm Q3 gauss meter : 0.0016697
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 5.07919
Current on Unser monitor : 11.8403
Current on Upstream bcm : 4.99271
Current on Downstream bcm : 5.16567
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 52.7858
Beam energy : 2564.25
MBSY1c magnet current (amp) : 106.728
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 3.07567e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 26
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 242.13
haSC200_6_Sensor_2_R : 26.38
haSC200_6_Sensor_3_R : 42.72
haSC200_6_Sensor_4_R : 41.72
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.61
haITC502_1_Sensor_3_R : 81.46
haITC502_4_Sensor_1_R : 87.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 96.04
haITC502_5_Sensor_2_R : 93.69
haITC502_5_Sensor_3_R : 267.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 85.77
haITC502_6_Sensor_3_R : 28.53
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3856
HacR_VPM_LVDT:VALr : -140
HacR_HPE1313A:0_Ch58 : -0.540039
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.737305
HacR_alignROLL : -0.255793
HacR_alignPITCH : -0.0166104
HacR_alignHPT : 1.48055
HacL_HPM_LVDT:VALr : -7012
HacL_VPM_LVDT:VALr : 1892
HacL_HPE1313A:0_Ch58 : -0.177734
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : 0.0136719
HacL_alignROLL : 0.354481
HacL_alignPITCH : -0.10636
HacL_alignHPT : 3.93174
Right Arm Angle Floor Angle : 23.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 23.491
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 15.973
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 184
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88