keyword=Start_Run_3588_RunType=Other,Tar=LD2-15cm,Rad=out,comment=triple
Beginning-of-run EPICS data for Run Number 3588 at Sat Apr 14 22:02:27 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=1000,ps3=10000,ps4=10000,ps5=10000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1566.39
Right Arm Q1 momentum : 2.08315
Right Arm Q1 gauss meter : -0.03896
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 896.581
Right Arm Q2 momentum : 2.08329
Right Arm Q2 gauss meter : 0.471
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 725.696
Right Arm D1 momentum : 2.083
Right Arm D1 NMR : 0.772976
Right Arm Q3 power supply current : 828.795
Right Arm Q3 momentum : 2.08288
Right Arm Q3 gauss meter : 0.3718
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 376.18
Left Arm Q1 momentum : 0.500019
Left Arm Q1 gauss meter : 0.03244
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 215.355
Left Arm Q2 momentum : 0.499869
Left Arm Q2 gauss meter : -0.11348
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 166.679
Left Arm D1 momentum : 0.500007
Left Arm D1 NMR : 0.185243
Left Arm Q3 power supply current : 199.044
Left Arm Q3 momentum : 0.499961
Left Arm Q3 gauss meter : 0.09993
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 1.09232
Current on Unser monitor : 7.62724
Current on Upstream bcm : 1.09201
Current on Downstream bcm : 1.09263
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 48.8564
Beam energy : 2564.25
MBSY1c magnet current (amp) : 106.728
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.161172
haBDSPOS : 3.07567e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 25
haL3_Fan_frequency_R : 36.5
haSC200_6_Sensor_1_R : 242.15
haSC200_6_Sensor_2_R : 26.48
haSC200_6_Sensor_3_R : 42.74
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 81.59
haITC502_4_Sensor_1_R : 88.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.76
haITC502_5_Sensor_2_R : 316.46
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 86.37
haITC502_6_Sensor_3_R : 28.54
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3861
HacR_VPM_LVDT:VALr : -156
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.736328
HacR_alignROLL : -0.254314
HacR_alignPITCH : -0.0170594
HacR_alignHPT : 1.48548
HacL_HPM_LVDT:VALr : -7015
HacL_VPM_LVDT:VALr : 1893
HacL_HPE1313A:0_Ch58 : -0.176758
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : 0.012207
HacL_alignROLL : 0.353552
HacL_alignPITCH : -0.107233
HacL_alignHPT : 3.93553
Right Arm Angle Floor Angle : 23.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 23.491
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 15.973
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 165
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88