User name adev
Log entry time 02:12:59 on April 15, 2001
Entry number 60544
keyword=End_of_Run_3595
****************************
Run Number: 3595
End of Run Comment:
RunType=Other,Tar=LD2-15cm,Rad=out,comment=triple,mode=singles,Lmom=0.0,Rmom=-2.083,Ene=2.561,Angle_R=23.491,Angle_L=15.973
Time of run = 4.2862467 min
Av. current (on 3x) = 1.7680581 uA
Av. current (on 1x) = 1.7396728 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 0.4474 | 0.4547 | 0.4595
up-down (mC)| 0.0052 | -0.0109 | -0.0028
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 1497.6079 Hz | 847035.4 /mC | 1497.608 Hz | 385147 | 1 | 860856.1 /mC
2 | 3120.9434 Hz | 1765181.4 /mC | 3.121 Hz | 802628 | 1000 | 1793983.0 /mC
3 | 35796.143 Hz | 20246022.0 /mC | 3.580 Hz | 9205866 | 10000 | 20576366.0 /mC
4 | 10488.294 Hz | 5932098.1 /mC | 1.049 Hz | 2697325 | 10000 | 6028889.1 /mC
5 | 14.974251 Hz | 8469.3 /mC | 0.001 Hz | 3851 | 10000 | 8607.5 /mC
Trigger 5 corrected for pulser:
5 (phys) | 4.817735 Hz | 2724.9 /mC | 0.000 Hz | 1239.0 | 10000 | 2769.3 /mC
8 | 1024.0 Hz | 579166.5 /mC | 0.016 Hz | 263347 | 65535 | 588616.4 /mC
output 1074.071 Hz
Av. deadtime from accepted triggers = 0.2865
Av. deadtime from gated scalers = 0.2861
Accepted triggers = 276224.00000
Rate of Left Arm Pulser for electronic DT = 10.156516
Rate of Right Arm Pulser for electronic DT = 10.354825
Rate of Left Arm Pulser&trig for electronic DT = 10.137074
Rate of Right Arm Pulser&trig for electronic DT = 10.354825
Left Arm Electronic DT = 0.001914242
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 74215.736
Rate of Right Arm Strobe = 5124.639
Signal | Charge (C)
upstream | 0.0004500
upstream 3x | 0.0004493
upstream 10x| 0.0004581
downstream | 0.0004448
downstream 3x | 0.0004602
downstream 10x| 0.0004609
****************************
End-of-run EPICS data for Run Number 3595 at Sun Apr 15 02:12:44 EDT 2001
Right Arm D1 momentum : 2.083
Right Arm arm angle : 23.4909
Left Arm D1 momentum : 0.500007
Left Arm arm angle : 15.973
Tiefenbach Hall A energy : 2560.65
Right Arm arm mispointing (HPT) : 1.49107
Left Arm arm mispointing (HPT) : 3.93482
Right Arm Q1 power supply current : 1566.49
Right Arm Q1 momentum : 2.08329
Right Arm Q1 gauss meter : -0.03896
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 896.529
Right Arm Q2 momentum : 2.08317
Right Arm Q2 gauss meter : 0.471
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 725.695
Right Arm D1 momentum : 2.083
Right Arm D1 NMR : 0.772975
Right Arm Q3 power supply current : 829.136
Right Arm Q3 momentum : 2.08373
Right Arm Q3 gauss meter : 0.3719
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 376.11
Left Arm Q1 momentum : 0.499926
Left Arm Q1 gauss meter : 0.03242
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 215.512
Left Arm Q2 momentum : 0.500493
Left Arm Q2 gauss meter : -0.11361
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 166.677
Left Arm D1 momentum : 0.500006
Left Arm D1 NMR : 0.185243
Left Arm Q3 power supply current : 199.144
Left Arm Q3 momentum : 0.500212
Left Arm Q3 gauss meter : 0.09996
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 1.74718
Current on Unser monitor : 8.54998
Current on Upstream bcm : 1.76898
Current on Downstream bcm : 1.72538
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 50.7302
MBSY1c Hall A Beam energy : 2564.25
MBSY1c magnet current (amp) : 106.728
MBSY1c Bdl : 639912
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 2560.65
Tiefenbach Hall C energy : 883.944
Delta(E)/E width (MV_AI_DXWID) : 1.02754
IPM1C12.XPOS : 0.00226864
IPM1H04A.XPOS : -2.01785
IPM1H04A.YPOS : 0.827307
IPM1H04B.XPOS : 0.0266663
IPM1H04B.YPOS : -0.121426
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -3866
HacR_VPM_LVDT:VALr : -164
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.736816
HacR_alignROLL : -0.254747
HacR_alignPITCH : -0.0184727
HacR_alignHPT : 1.49104
HacL_HPM_LVDT:VALr : -7015
HacL_VPM_LVDT:VALr : 1893
HacL_HPE1313A:0_Ch58 : -0.17627
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : 0.0117188
HacL_alignROLL : 0.353087
HacL_alignPITCH : -0.108106
HacL_alignHPT : 3.93576
haBDSPOS : 3.07567e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 25.5
haL3_Fan_frequency_R : 37
haH2_P_Fill_Target_R : 20.15
haH2_P_Exhaust_R : 20.82
haH2_P_Fill_Bottle_R : 20.14
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.32
haD2_P_Fill_Bottle_R : 37.91
haD2_DP_Fill_Exhaust_R : 0.0747
haSC200_6_Sensor_1_R : 242.11
haSC200_6_Sensor_2_R : 26.46
haSC200_6_Sensor_3_R : 42.72
haSC200_6_Sensor_4_R : 41.71
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 81.82
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.01
haITC502_4_Sensor_1_R : 88.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.06
haITC502_5_Sensor_2_R : 97.01
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 86.63
haITC502_6_Sensor_3_R : 28.53
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.617041
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 193
Laser power Hall A : 57
Half-wave plate (off=out) : OFF