Log entry time 03:28:45 on April 15, 2001
Entry number 60557
keyword=Start_Run_3605_RunType=Other,Tar=LD2-15cm,Rad=out,comment=triple,mode=singles,Lmom=0.0,Rmom=-2.083,Ene=2.561,Angle_R=23.491,Angle_L=15.973
Beginning-of-run EPICS data for Run Number 3605 at Sun Apr 15 03:28:32 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=1000,ps3=10000,ps4=10000,ps5=10000,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1566.39
Right Arm Q1 momentum : 2.08315
Right Arm Q1 gauss meter : -0.03896
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 896.256
Right Arm Q2 momentum : 2.0826
Right Arm Q2 gauss meter : 0.4709
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 725.693
Right Arm D1 momentum : 2.083
Right Arm D1 NMR : 0.772976
Right Arm Q3 power supply current : 828.975
Right Arm Q3 momentum : 2.08333
Right Arm Q3 gauss meter : 0.3718
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 376.075
Left Arm Q1 momentum : 0.499879
Left Arm Q1 gauss meter : 0.03243
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 215.122
Left Arm Q2 momentum : 0.499586
Left Arm Q2 gauss meter : -0.11353
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 166.677
Left Arm D1 momentum : 0.500009
Left Arm D1 NMR : 0.185244
Left Arm Q3 power supply current : 199.088
Left Arm Q3 momentum : 0.500071
Left Arm Q3 gauss meter : 0.09994
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 1.84905
Current on Unser monitor : 9.1053
Current on Upstream bcm : 1.86438
Current on Downstream bcm : 1.75732
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 1.78157
Beam energy : 2564.25
MBSY1c magnet current (amp) : 106.728
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.161172
haBDSPOS : 3.07567e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 24.5
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 26.5
haSC200_6_Sensor_3_R : 42.72
haSC200_6_Sensor_4_R : 41.69
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 81.7
haITC502_4_Sensor_1_R : 88.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.06
haITC502_5_Sensor_2_R : 0.05
haITC502_5_Sensor_3_R : 970.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 86.78
haITC502_6_Sensor_3_R : 28.54
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3867
HacR_VPM_LVDT:VALr : -163
HacR_HPE1313A:0_Ch58 : -0.538086
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.73584
HacR_alignROLL : -0.253761
HacR_alignPITCH : -0.0175748
HacR_alignHPT : 1.49188
HacL_HPM_LVDT:VALr : -7014
HacL_VPM_LVDT:VALr : 1891
HacL_HPE1313A:0_Ch58 : -0.17627
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : 0.0117188
HacL_alignROLL : 0.35301
HacL_alignPITCH : -0.108032
HacL_alignHPT : 3.93356
Right Arm Angle Floor Angle : 23.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 23.4909
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 15.973
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 176
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88