User name adev
Log entry time 11:12:52 on April 15, 2001
Entry number 60591
keyword=Start_Run_3619_RunType=Other,Tar=LD2-15cm,Rad=out,comment=triple,mode=coincidence,Lmom=-2.106,Rmom=.980,Ene=2.561,Angle_R=56.98,Angle_L=15.973
Beginning-of-run EPICS data for Run Number 3619 at Sun Apr 15 11:12:43 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=500,ps2=1000,ps3=10000,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 736.995
Right Arm Q1 momentum : 0.980131
Right Arm Q1 gauss meter : 0.018564
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 421.612
Right Arm Q2 momentum : 0.979656
Right Arm Q2 gauss meter : -0.2224
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 337.053
Right Arm D1 momentum : 0.98
Right Arm D1 NMR : 0.363666
Right Arm Q3 power supply current : 389.883
Right Arm Q3 momentum : 0.97983
Right Arm Q3 gauss meter : -0.17509
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1584.2
Left Arm Q1 momentum : 2.10573
Left Arm Q1 gauss meter : -0.13391
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 906.649
Left Arm Q2 momentum : 2.10555
Left Arm Q2 gauss meter : 0.4782
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 717.24
Left Arm D1 momentum : 2.10601
Left Arm D1 NMR : 0.779274
Left Arm Q3 power supply current : 838.418
Left Arm Q3 momentum : 2.10595
Left Arm Q3 gauss meter : -0.4182
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 10.3629
Current on Unser monitor : 17.6213
Current on Upstream bcm : 10.3402
Current on Downstream bcm : 10.3856
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 10.4786
Beam energy : 2564.25
MBSY1c magnet current (amp) : 106.728
Radiator 5V Linear Supply : 5.00122
Radiator Encoder : 0.166056
haBDSPOS : 3.07567e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 24.5
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 242.26
haSC200_6_Sensor_2_R : 26.5
haSC200_6_Sensor_3_R : 42.84
haSC200_6_Sensor_4_R : 41.71
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 81.82
haITC502_4_Sensor_1_R : 88.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 317.85
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 970
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 86.51
haITC502_6_Sensor_3_R : 28.53
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4642
HacR_VPM_LVDT:VALr : 514
HacR_HPE1313A:0_Ch58 : -0.514648
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.793457
HacR_alignROLL : -0.312378
HacR_alignPITCH : -0.0396415
HacR_alignHPT : 2.2789
HacL_HPM_LVDT:VALr : -7082
HacL_VPM_LVDT:VALr : 2224
HacL_HPE1313A:0_Ch58 : -0.173828
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : 0.0375977
HacL_alignROLL : 0.378109
HacL_alignPITCH : -0.110216
HacL_alignHPT : 3.99973
Right Arm Angle Floor Angle : 57
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 56.9856
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 15.9726
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 107
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88