User name adev
Log entry time 21:00:17 on April 15, 2001
Entry number 60614
keyword=Start_Run_3629_RunType=Other,Tar=LD2-15cm,Rad=out,comment=triple
Beginning-of-run EPICS data for Run Number 3629 at Sun Apr 15 21:00:07 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=500,ps2=1000,ps3=10000,ps4=10000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 736.925
Right Arm Q1 momentum : 0.980038
Right Arm Q1 gauss meter : 0.018556
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 421.767
Right Arm Q2 momentum : 0.980016
Right Arm Q2 gauss meter : -0.2225
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 337.055
Right Arm D1 momentum : 0.980001
Right Arm D1 NMR : 0.363667
Right Arm Q3 power supply current : 389.853
Right Arm Q3 momentum : 0.979754
Right Arm Q3 gauss meter : -0.1751
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1584.31
Left Arm Q1 momentum : 2.10587
Left Arm Q1 gauss meter : -0.13394
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 906.773
Left Arm Q2 momentum : 2.10584
Left Arm Q2 gauss meter : 0.4783
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 717.231
Left Arm D1 momentum : 2.106
Left Arm D1 NMR : 0.779268
Left Arm Q3 power supply current : 838.423
Left Arm Q3 momentum : 2.10596
Left Arm Q3 gauss meter : -0.4182
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 9.80552
Current on Unser monitor : 16.8922
Current on Upstream bcm : 9.78491
Current on Downstream bcm : 9.82614
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 9.89241
Beam energy : 2564.25
MBSY1c magnet current (amp) : 106.728
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.161172
haBDSPOS : 3.07567e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 25.5
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 242.25
haSC200_6_Sensor_2_R : 26.6
haSC200_6_Sensor_3_R : 42.91
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.08
haITC502_4_Sensor_1_R : 88.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 26.76
haITC502_5_Sensor_2_R : 319.61
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.09
haITC502_6_Sensor_3_R : 28.53
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4627
HacR_VPM_LVDT:VALr : 516
HacR_HPE1313A:0_Ch58 : -0.512207
HacR_HPE1313A:0_Ch55 : 23.1445
HacR_HPE1313A:0_Ch54 : -0.797363
HacR_alignROLL : -0.31583
HacR_alignPITCH : -0.0427844
HacR_alignHPT : 2.26311
HacL_HPM_LVDT:VALr : -7095
HacL_VPM_LVDT:VALr : 2224
HacL_HPE1313A:0_Ch58 : -0.17334
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : 0.0371094
HacL_alignROLL : 0.377644
HacL_alignPITCH : -0.110652
HacL_alignHPT : 4.01559
Right Arm Angle Floor Angle : 57
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 56.9857
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 15.9725
Wien angle : 57.1655
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1290.7
Wien field : 37.497
Laser attenuation Hall A : 103
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88