User name adev
Log entry time 10:40:37 on April 16, 2001
Entry number 60632
keyword=Start_Run_3637_RunType=Cosmic,Tar=9foil-12C,Rad=out,comment=Bob
Beginning-of-run EPICS data for Run Number 3637 at Mon Apr 16 10:40:22 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2255.89
Right Arm Q1 momentum : 3.00011
Right Arm Q1 gauss meter : -0.05603
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1291.04
Right Arm Q2 momentum : 2.99985
Right Arm Q2 gauss meter : 0.6774
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 97.2483
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.708769
Right Arm Q3 power supply current : 1193.62
Right Arm Q3 momentum : 2.99972
Right Arm Q3 gauss meter : 0.5351
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0001766
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.120852
Left Arm Q2 momentum : 0.000280659
Left Arm Q2 gauss meter : 0.0011121
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : -0.00174692
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.177496
Left Arm Q3 power supply current : 1.94391
Left Arm Q3 momentum : 0.00488274
Left Arm Q3 gauss meter : -7.5e-05
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0504738
Current on Unser monitor : 7.14394
Current on Upstream bcm : 0.053931
Current on Downstream bcm : 0.0470166
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
Beam energy : 5749.64
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 5.02808
Radiator Encoder : 0.156288
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 26
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.2
haSC200_6_Sensor_2_R : 27.05
haSC200_6_Sensor_3_R : 43.01
haSC200_6_Sensor_4_R : 41.79
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 84.16
haITC502_4_Sensor_1_R : 90.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.06
haITC502_5_Sensor_2_R : 0.05
haITC502_5_Sensor_3_R : 990.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 88.96
haITC502_6_Sensor_3_R : 28.51
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -767
HacR_VPM_LVDT:VALr : -262
HacR_HPE1313A:0_Ch58 : -0.535645
HacR_HPE1313A:0_Ch55 : 23.0957
HacR_HPE1313A:0_Ch54 : -0.802734
HacR_alignROLL : -0.321254
HacR_alignPITCH : -0.0207841
HacR_alignHPT : -1.93859
HacL_HPM_LVDT:VALr : -8093
HacL_VPM_LVDT:VALr : 2025
HacL_HPE1313A:0_Ch58 : -0.133301
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.1875
HacL_alignROLL : 0.140002
HacL_alignPITCH : -0.125469
HacL_alignHPT : 5.25819
Right Arm Angle Floor Angle : 18
Right Arm Angle Vernier : 27
Right Arm Scattering Angle : 18.3658
Left Arm Angle Floor Angle : 21.5
Left Arm Angle Vernier : -20
Left Arm Scattering Angle : 21.1703
Wien angle : 21.6589
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -476.81
Wien field : 13.635
Laser attenuation Hall A : 50
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88