User name adev
Log entry time 10:44:37 on April 16, 2001
Entry number 60634
keyword=Start_Run_3638_RunType=Cosmic,Tar=9foil-12C,Rad=out,comment=Bob
Beginning-of-run EPICS data for Run Number 3638 at Mon Apr 16 10:44:22 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2255.89
Right Arm Q1 momentum : 3.00011
Right Arm Q1 gauss meter : -0.05602
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1291.14
Right Arm Q2 momentum : 3.00009
Right Arm Q2 gauss meter : 0.6774
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 133.301
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.674827
Right Arm Q3 power supply current : 1193.83
Right Arm Q3 momentum : 3.00027
Right Arm Q3 gauss meter : 0.5351
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0001716
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.40849
Left Arm Q2 momentum : 0.000948653
Left Arm Q2 gauss meter : 0.0010978
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1.18044
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.452003
Left Arm Q3 power supply current : 1.93439
Left Arm Q3 momentum : 0.00485882
Left Arm Q3 gauss meter : -9.03e-05
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0503829
Current on Unser monitor : 7.4029
Current on Upstream bcm : 0.0534904
Current on Downstream bcm : 0.0472753
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
Beam energy : 5749.64
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.15873
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 25.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.25
haSC200_6_Sensor_2_R : 27.03
haSC200_6_Sensor_3_R : 43.01
haSC200_6_Sensor_4_R : 41.79
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 83.74
haITC502_4_Sensor_1_R : 90.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.05
haITC502_5_Sensor_2_R : 96.65
haITC502_5_Sensor_3_R : 10
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 88.98
haITC502_6_Sensor_3_R : 28.51
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -769
HacR_VPM_LVDT:VALr : -261
HacR_HPE1313A:0_Ch58 : -0.536133
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.802734
HacR_alignROLL : -0.321371
HacR_alignPITCH : -0.0197532
HacR_alignHPT : -1.93852
HacL_HPM_LVDT:VALr : -8093
HacL_VPM_LVDT:VALr : 2027
HacL_HPE1313A:0_Ch58 : -0.133301
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.1875
HacL_alignROLL : 0.167907
HacL_alignPITCH : -0.12598
HacL_alignHPT : 5.22692
Right Arm Angle Floor Angle : 18
Right Arm Angle Vernier : 27
Right Arm Scattering Angle : 18.3658
Left Arm Angle Floor Angle : 21.5
Left Arm Angle Vernier : -20
Left Arm Scattering Angle : 21.1703
Wien angle : -17.8222
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -451.35
Wien field : 12.898
Laser attenuation Hall A : 50
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88