User name adev
Log entry time 21:47:28 on April 17, 2001
Entry number 60687
keyword=End_of_Run_3651
****************************
Run Number: 3651
End of Run Comment:
RunType=Cosmic,Tar=9foil-12C,Rad=out,comment=test if all cables are there,mode=coincidence,Lmom=1.8900,Rmom=-3.16,Ene=none,Angle_R=18.365,Angle_L=21.17
Time of run = 221.62128 min
Av. current (on 3x) = 0.0035420786 uA
Av. current (on 1x) = -0.020741089 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| -0.2758 | 0.0471 | 0.2934
up-down (mC)| 0.4146 | -0.4520 | -0.0238
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 17.313921 Hz | 4888067.9 /mC | 17.314 Hz | 230228 | 1 | -834764.3 /mC
2 | 1237.0245 Hz | 349236900.0 /mC | 1.237 Hz | 16449058 | 1000 | -59641255.0 /mC
3 | 17.885316 Hz | 5049384.3 /mC | 17.885 Hz | 237826 | 1 | -862313.3 /mC
4 | 844.77416 Hz | 238496730.0 /mC | 0.845 Hz | 11233196 | 1000 | -40729500.0 /mC
5 | 10.171481 Hz | 2871613.6 /mC | 10.171 Hz | 135253 | 1 | -490402.5 /mC
Trigger 5 corrected for pulser:
5 (phys) | 0.000301 Hz | 85.0 /mC | 0.000 Hz | 4.0021231 | 1 | -14.5 /mC
8 | 1024.0 Hz | 289095800.0 /mC | 0.016 Hz | 13616412 | 65535 | -49370602.0 /mC
output 27.030 Hz
Av. deadtime from accepted triggers = 0.0035
Av. deadtime from gated scalers = 0.0038
Accepted triggers = 359428.00000
Rate of Left Arm Pulser for electronic DT = 10.17118
Rate of Right Arm Pulser for electronic DT = 10.173361
Rate of Left Arm Pulser&trig for electronic DT = 10.17118
Rate of Right Arm Pulser&trig for electronic DT = 10.173361
Left Arm Electronic DT = 0.0
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 1274.9619
Rate of Right Arm Strobe = 1419.4335
Signal | Charge (C)
upstream | -0.0000685
upstream 3x | -0.0001789
upstream 10x| 0.0002815
downstream | -0.0004831
downstream 3x | 0.0002731
downstream 10x| 0.0003053
****************************
End-of-run EPICS data for Run Number 3651 at Tue Apr 17 21:47:18 EDT 2001
Right Arm D1 momentum : 3.16
Right Arm arm angle : 18.3648
Left Arm D1 momentum : 1.89
Left Arm arm angle : 21.1699
Tiefenbach Hall A energy : 5737.55
Right Arm arm mispointing (HPT) : -1.80083
Left Arm arm mispointing (HPT) : 5.29307
Right Arm Q1 power supply current : 2376.19
Right Arm Q1 momentum : 3.16009
Right Arm Q1 gauss meter : -0.05901
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1359.9
Right Arm Q2 momentum : 3.15985
Right Arm Q2 gauss meter : 0.7139
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1141.55
Right Arm D1 momentum : 3.16
Right Arm D1 NMR : 1.17264
Right Arm Q3 power supply current : 1257.53
Right Arm Q3 momentum : 3.16035
Right Arm Q3 gauss meter : 0.5639
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1421.77
Left Arm Q1 momentum : 1.88982
Left Arm Q1 gauss meter : 0.12082
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 813.645
Left Arm Q2 momentum : 1.88956
Left Arm Q2 gauss meter : -0.4289
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 639.376
Left Arm D1 momentum : 1.89
Left Arm D1 NMR : 0.69939
Left Arm Q3 power supply current : 752.44
Left Arm Q3 momentum : 1.88999
Left Arm Q3 gauss meter : 0.3758
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.047756
Current on Unser monitor : 8.63355
Current on Upstream bcm : 0.0497893
Current on Downstream bcm : 0.0466241
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 5749.64
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.43483e+06
MBSY3c Hall C Beam energy : 2339.14
Tiefenbach Hall A energy : 5737.55
Tiefenbach Hall C energy : 2333.56
Delta(E)/E width (MV_AI_DXWID) : 0.934573
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.615234
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -896
HacR_VPM_LVDT:VALr : -185
HacR_HPE1313A:0_Ch58 : -0.527832
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.794434
HacR_alignROLL : -0.313599
HacR_alignPITCH : -0.0277011
HacR_alignHPT : -1.80079
HacL_HPM_LVDT:VALr : -8148
HacL_VPM_LVDT:VALr : 1993
HacL_HPE1313A:0_Ch58 : -0.135742
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.19043
HacL_alignROLL : 0.165698
HacL_alignPITCH : -0.124233
HacL_alignHPT : 5.29278
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 26.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 19.75
haH2_P_Exhaust_R : 20.38
haH2_P_Fill_Bottle_R : 19.74
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.07
haD2_P_Fill_Bottle_R : 37.44
haD2_DP_Fill_Exhaust_R : 0.0744
haSC200_6_Sensor_1_R : 241.48
haSC200_6_Sensor_2_R : 27.19
haSC200_6_Sensor_3_R : 43.01
haSC200_6_Sensor_4_R : 41.66
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 84.62
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.02
haITC502_4_Sensor_1_R : 91
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 97.67
haITC502_5_Sensor_2_R : 26.77
haITC502_5_Sensor_3_R : 3276.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 89.77
haITC502_6_Sensor_3_R : 28.47
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.617041
Wien angle : -44.2804
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -1080.8
Wien field : 30.679
Laser attenuation Hall A : 210
Laser power Hall A : 57
Half-wave plate (off=out) : OFF