User name adev
Log entry time 21:51:52 on April 18, 2001
Entry number 60722
keyword=Start_Run_3663_RunType=Optics,Tar=9foil-12C,Rad=out,comment=test
Beginning-of-run EPICS data for Run Number 3663 at Wed Apr 18 21:51:41 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=200,ps2=800,ps3=50,ps4=400,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2375.1
Right Arm Q1 momentum : 3.15865
Right Arm Q1 gauss meter : -0.05899
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1359.47
Right Arm Q2 momentum : 3.15887
Right Arm Q2 gauss meter : 0.7137
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1140.97
Right Arm D1 momentum : 3.1588
Right Arm D1 NMR : 1.17219
Right Arm Q3 power supply current : 1256.86
Right Arm Q3 momentum : 3.15867
Right Arm Q3 gauss meter : 0.5637
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1131.86
Left Arm Q1 momentum : 1.50448
Left Arm Q1 gauss meter : 0.09646
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 648.048
Left Arm Q2 momentum : 1.50499
Left Arm Q2 gauss meter : -0.3417
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 504.131
Left Arm D1 momentum : 1.5049
Left Arm D1 NMR : 0.556977
Left Arm Q3 power supply current : 599.384
Left Arm Q3 momentum : 1.50554
Left Arm Q3 gauss meter : 0.2992
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 47.0254
Current on Unser monitor : 53.6929
Current on Upstream bcm : 46.8923
Current on Downstream bcm : 47.1585
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 52.3458
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.175824
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.05
haSC200_6_Sensor_2_R : 27.12
haSC200_6_Sensor_3_R : 43.44
haSC200_6_Sensor_4_R : 41.86
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 83.44
haITC502_4_Sensor_1_R : 90
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 97.19
haITC502_5_Sensor_2_R : 26.55
haITC502_5_Sensor_3_R : 3264.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 88.84
haITC502_6_Sensor_3_R : 28.69
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3311
HacR_VPM_LVDT:VALr : 333
HacR_HPE1313A:0_Ch58 : -0.518066
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.818848
HacR_alignROLL : -0.338048
HacR_alignPITCH : -0.0358966
HacR_alignHPT : 0.918669
HacL_HPM_LVDT:VALr : -8684
HacL_VPM_LVDT:VALr : -894
HacL_HPE1313A:0_Ch58 : -0.302734
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.369629
HacL_alignROLL : 0.0017243
HacL_alignPITCH : 0.0251768
HacL_alignHPT : 5.96928
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : 18
Right Arm Scattering Angle : 20.2945
Left Arm Angle Floor Angle : 47
Left Arm Angle Vernier : -14.1
Left Arm Scattering Angle : 46.6993
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 217
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88