User name adev
Log entry time 22:09:52 on April 18, 2001
Entry number 60725
keyword=Start_Run_3665_RunType=Optics,Tar=LH2-15cm,Rad=out,comment=test
Beginning-of-run EPICS data for Run Number 3665 at Wed Apr 18 22:09:40 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=200,ps2=800,ps3=50,ps4=400,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2375.1
Right Arm Q1 momentum : 3.15865
Right Arm Q1 gauss meter : -0.05899
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1359.7
Right Arm Q2 momentum : 3.15939
Right Arm Q2 gauss meter : 0.7137
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1140.97
Right Arm D1 momentum : 3.1588
Right Arm D1 NMR : 1.17219
Right Arm Q3 power supply current : 1256.89
Right Arm Q3 momentum : 3.15875
Right Arm Q3 gauss meter : 0.5636
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1131.83
Left Arm Q1 momentum : 1.50443
Left Arm Q1 gauss meter : 0.09645
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 648.004
Left Arm Q2 momentum : 1.50489
Left Arm Q2 gauss meter : -0.3417
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 504.135
Left Arm D1 momentum : 1.5049
Left Arm D1 NMR : 0.556976
Left Arm Q3 power supply current : 599.068
Left Arm Q3 momentum : 1.50475
Left Arm Q3 gauss meter : 0.2991
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.9492
Current on Unser monitor : 55.6884
Current on Upstream bcm : 48.8716
Current on Downstream bcm : 49.0269
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 95.004
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 68.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.81
haSC200_6_Sensor_2_R : 27.03
haSC200_6_Sensor_3_R : 43.36
haSC200_6_Sensor_4_R : 41.77
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 83.08
haITC502_4_Sensor_1_R : 89.8
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 326.17
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 994.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 88.57
haITC502_6_Sensor_3_R : 28.67
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3312
HacR_VPM_LVDT:VALr : 333
HacR_HPE1313A:0_Ch58 : -0.519043
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.820801
HacR_alignROLL : -0.340136
HacR_alignPITCH : -0.0348651
HacR_alignHPT : 0.919859
HacL_HPM_LVDT:VALr : -8674
HacL_VPM_LVDT:VALr : -887
HacL_HPE1313A:0_Ch58 : -0.302246
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.370117
HacL_alignROLL : 0.00284407
HacL_alignPITCH : 0.0253889
HacL_alignHPT : 5.9598
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : 18
Right Arm Scattering Angle : 20.2945
Left Arm Angle Floor Angle : 47
Left Arm Angle Vernier : -14.1
Left Arm Scattering Angle : 46.6994
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 232
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88