Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:54:40 on April 18, 2001
Entry number 60738
keyword=Start_Run_3669_RunType=Optics,Tar=9foil-12C,Rad=out,comment=test
Beginning-of-run EPICS data for Run Number 3669 at Wed Apr 18 23:54:27 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=800,ps3=2,ps4=550,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2098.95
Right Arm Q1 momentum : 2.7914
Right Arm Q1 gauss meter : -0.0522
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1201.29
Right Arm Q2 momentum : 2.79131
Right Arm Q2 gauss meter : 0.631
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 992.493
Right Arm D1 momentum : 2.7914
Right Arm D1 NMR : 1.03585
Right Arm Q3 power supply current : 1110.51
Right Arm Q3 momentum : 2.79086
Right Arm Q3 gauss meter : 0.4981
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1447.49
Left Arm Q1 momentum : 1.92401
Left Arm Q1 gauss meter : 0.12301
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 828.496
Left Arm Q2 momentum : 1.92405
Left Arm Q2 gauss meter : -0.4366
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 651.941
Left Arm D1 momentum : 1.9243
Left Arm D1 NMR : 0.712074
Left Arm Q3 power supply current : 766.059
Left Arm Q3 momentum : 1.92421
Left Arm Q3 gauss meter : 0.3825
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 66.9566
Current on Unser monitor : 75.2861
Current on Upstream bcm : 66.8646
Current on Downstream bcm : 67.0486
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 117.632
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.166056
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.64
haSC200_6_Sensor_2_R : 26.92
haSC200_6_Sensor_3_R : 43.24
haSC200_6_Sensor_4_R : 41.77
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.7
haITC502_4_Sensor_1_R : 89.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.94
haITC502_5_Sensor_2_R : 324.75
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.78
haITC502_6_Sensor_3_R : 28.5
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3965
HacR_VPM_LVDT:VALr : 61
HacR_HPE1313A:0_Ch58 : -0.549805
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.746582
HacR_alignROLL : -0.266252
HacR_alignPITCH : -0.00652042
HacR_alignHPT : 1.58442
HacL_HPM_LVDT:VALr : -6627
HacL_VPM_LVDT:VALr : 173
HacL_HPE1313A:0_Ch58 : -0.209961
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.262207
HacL_alignROLL : 0.100471
HacL_alignPITCH : -0.0562593
HacL_alignHPT : 3.62348
Right Arm Angle Floor Angle : 25.5
Right Arm Angle Vernier : 52.6
Right Arm Scattering Angle : 25.9894
Left Arm Angle Floor Angle : 40
Left Arm Angle Vernier : -57.3
Left Arm Scattering Angle : 39.4662
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 284
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88