User name adev
Log entry time 02:01:07 on April 19, 2001
Entry number 60746
keyword=Start_Run_3671_RunType=Optics,Tar=dum-15cm,Rad=out,comment=ep_scan,mode=coincidence,Lmom=3.1563,Rmom=1.6395,Ene=3995,Angle_R=48.485,Angle_L=22.866
Beginning-of-run EPICS data for Run Number 3671 at Thu Apr 19 02:00:57 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=155,ps3=2,ps4=180,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1232.88
Right Arm Q1 momentum : 1.6396
Right Arm Q1 gauss meter : -0.03075
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 705.567
Right Arm Q2 momentum : 1.63945
Right Arm Q2 gauss meter : 0.3709
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 562.651
Right Arm D1 momentum : 1.63951
Right Arm D1 NMR : 0.608404
Right Arm Q3 power supply current : 652.645
Right Arm Q3 momentum : 1.64019
Right Arm Q3 gauss meter : 0.2927
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2374.78
Left Arm Q1 momentum : 3.15657
Left Arm Q1 gauss meter : 0.20126
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1359.31
Left Arm Q2 momentum : 3.15678
Left Arm Q2 gauss meter : -0.7154
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1111.21
Left Arm D1 momentum : 3.1563
Left Arm D1 NMR : 1.16884
Left Arm Q3 power supply current : 1256.55
Left Arm Q3 momentum : 3.15621
Left Arm Q3 gauss meter : 0.627
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.8746
Current on Unser monitor : 35.8804
Current on Upstream bcm : 28.8816
Current on Downstream bcm : 28.8677
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.1778
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.17094
haBDSPOS : 1.70075e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.56
haSC200_6_Sensor_2_R : 26.85
haSC200_6_Sensor_3_R : 43.21
haSC200_6_Sensor_4_R : 41.71
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.61
haITC502_4_Sensor_1_R : 88.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 98.84
haITC502_5_Sensor_2_R : 96.95
haITC502_5_Sensor_3_R : 268.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.58
haITC502_6_Sensor_3_R : 28.63
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4692
HacR_VPM_LVDT:VALr : 439
HacR_HPE1313A:0_Ch58 : -0.533691
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.871094
HacR_alignROLL : -0.390531
HacR_alignPITCH : -0.0212661
HacR_alignHPT : 2.41594
HacL_HPM_LVDT:VALr : -6807
HacL_VPM_LVDT:VALr : 2178
HacL_HPE1313A:0_Ch58 : -0.137207
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.17334
HacL_alignROLL : 0.181165
HacL_alignPITCH : -0.122477
HacL_alignHPT : 3.78475
Right Arm Angle Floor Angle : 48
Right Arm Angle Vernier : 52.8
Right Arm Scattering Angle : 48.485
Left Arm Angle Floor Angle : 23
Left Arm Angle Vernier : 12.2
Left Arm Scattering Angle : 22.8657
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 164
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88