User name adev
Log entry time 03:48:17 on April 19, 2001
Entry number 60758
keyword=Start_Run_3676_RunType=Optics,Tar=9foil-12C,Rad=out,comment=ep_scan,mode=singles,Lmom=3.2858,Rmom=1.5152,Ene=3995,Angle_R=51.986,Angle_L=21.283
Beginning-of-run EPICS data for Run Number 3676 at Thu Apr 19 03:48:06 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=150,ps3=1,ps4=200,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1139.35
Right Arm Q1 momentum : 1.51523
Right Arm Q1 gauss meter : -0.02844
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 652.305
Right Arm Q2 momentum : 1.51569
Right Arm Q2 gauss meter : 0.3428
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 518.749
Right Arm D1 momentum : 1.5152
Right Arm D1 NMR : 0.562273
Right Arm Q3 power supply current : 602.682
Right Arm Q3 momentum : 1.51462
Right Arm Q3 gauss meter : 0.2704
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2472.16
Left Arm Q1 momentum : 3.28599
Left Arm Q1 gauss meter : 0.20948
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1414.82
Left Arm Q2 momentum : 3.28569
Left Arm Q2 gauss meter : -0.7444
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1163.09
Left Arm D1 momentum : 3.2858
Left Arm D1 NMR : 1.21689
Left Arm Q3 power supply current : 1308.1
Left Arm Q3 momentum : 3.28571
Left Arm Q3 gauss meter : 0.6528
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 67.41
Current on Unser monitor : 75.2959
Current on Upstream bcm : 67.328
Current on Downstream bcm : 67.5124
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 68.4584
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 4.99878
Radiator Encoder : 0.161172
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.53
haSC200_6_Sensor_2_R : 26.82
haSC200_6_Sensor_3_R : 43.21
haSC200_6_Sensor_4_R : 41.69
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.27
haITC502_4_Sensor_1_R : 88.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.9
haITC502_5_Sensor_2_R : 324.48
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.64
haITC502_6_Sensor_3_R : 28.54
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4759
HacR_VPM_LVDT:VALr : 379
HacR_HPE1313A:0_Ch58 : -0.524414
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.816406
HacR_alignROLL : -0.335815
HacR_alignPITCH : -0.0297941
HacR_alignHPT : 2.45912
HacL_HPM_LVDT:VALr : -6933
HacL_VPM_LVDT:VALr : 2430
HacL_HPE1313A:0_Ch58 : -0.137695
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.136719
HacL_alignROLL : 0.214
HacL_alignPITCH : -0.121316
HacL_alignHPT : 3.91201
Right Arm Angle Floor Angle : 51.5
Right Arm Angle Vernier : 53
Right Arm Scattering Angle : 51.9858
Left Arm Angle Floor Angle : 21.5
Left Arm Angle Vernier : -2
Left Arm Scattering Angle : 21.283
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 269
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88