Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 04:51:49 on April 19, 2001
Entry number 60764
keyword=Start_Run_3678_RunType=pion_prod,Tar=dum-15cm,Rad=out,comment=ep_scan,mode=coincidence,Lmom=3.4476,Rmom=1.3593,Ene=3995,Angle_R=56.981,Angle_L=19.28
Beginning-of-run EPICS data for Run Number 3678 at Thu Apr 19 04:51:40 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=150,ps3=3,ps4=210,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1022.1
Right Arm Q1 momentum : 1.3593
Right Arm Q1 gauss meter : -0.02553
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 584.911
Right Arm Q2 momentum : 1.3591
Right Arm Q2 gauss meter : 0.3075
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 462.172
Right Arm D1 momentum : 1.35922
Right Arm D1 NMR : 0.504391
Right Arm Q3 power supply current : 540.939
Right Arm Q3 momentum : 1.35945
Right Arm Q3 gauss meter : 0.2425
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2593.96
Left Arm Q1 momentum : 3.44789
Left Arm Q1 gauss meter : 0.21977
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1484.75
Left Arm Q2 momentum : 3.4481
Left Arm Q2 gauss meter : -0.7809
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1230.83
Left Arm D1 momentum : 3.44761
Left Arm D1 NMR : 1.27693
Left Arm Q3 power supply current : 1372.54
Left Arm Q3 momentum : 3.44756
Left Arm Q3 gauss meter : 0.6848
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.8858
Current on Unser monitor : 36.7257
Current on Upstream bcm : 28.9198
Current on Downstream bcm : 28.8517
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.1979
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.153846
haBDSPOS : 1.70075e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.79
haSC200_6_Sensor_2_R : 0
haSC200_6_Sensor_3_R : 43.36
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.64
haITC502_4_Sensor_1_R : 88.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.62
haITC502_6_Sensor_3_R : 28.6
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4777
HacR_VPM_LVDT:VALr : 630
HacR_HPE1313A:0_Ch58 : -0.515625
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.805176
HacR_alignROLL : -0.323868
HacR_alignPITCH : -0.0380071
HacR_alignHPT : 2.4353
HacL_HPM_LVDT:VALr : -7170
HacL_VPM_LVDT:VALr : 2607
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0893555
HacL_alignROLL : 0.25685
HacL_alignPITCH : -0.148085
HacL_alignHPT : 4.15514
Right Arm Angle Floor Angle : 56.5
Right Arm Angle Vernier : 52.2
Right Arm Scattering Angle : 56.9814
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -2.2
Left Arm Scattering Angle : 19.2802
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 168
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88