• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 04:56:40 on April 19, 2001

    Entry number 60766

    keyword=End_of_Run_3678
    ****************************
     Run Number: 3678
    End of Run Comment:
    RunType=pion_prod,Tar=dum-15cm,Rad=out,comment=ep_scan,mode=coincidence,Lmom=3.4476,Rmom=1.3593,Ene=3995,Angle_R=56.981,Angle_L=19.28
    
    Time of run = 5.4795247 min
    Av. current (on 3x) = 14.500041 uA
    Av. current (on 1x) = 29.000691 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    9.5346  |    4.7672  |    9.5853
    up-down    (mC)|   -0.0873  |    9.5493  |   -0.0405
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 37.49717 Hz  |      2586.0 /mC  |   37.497 Hz  |     12328  |     1   |      1293.0 /mC
        2      | 7601.6204 Hz  |    524248.2 /mC  |   50.677 Hz  |   2499196  |   150   |    262118.6 /mC
        3      | 127.30119 Hz  |      8779.4 /mC  |   42.434 Hz  |     41853  |     3   |      4389.6 /mC
        4      | 10570.634 Hz  |    729007.2 /mC  |   50.336 Hz  |   3475323  |   210   |    364495.9 /mC
        5      | 10.159032 Hz  |       700.6 /mC  |   10.159 Hz  |      3340  |     1   |       350.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.0 Hz  |         0.0 /mC  |    0.000 Hz  | 1.399264e-05  |     1   |         0.0 /mC
        8    | 1024.0 Hz  |     70620.5 /mC  |    0.016 Hz  |    336662  | 65535   |     35309.5 /mC
        output                       174.121 Hz
    Av. deadtime from accepted triggers = 0.0194
    Av. deadtime from gated scalers = 0.0234
    Accepted triggers  =  57246.00000
    Rate of Left Arm Pulser for electronic DT  = 10.159032
    Rate of Right Arm Pulser for electronic DT  = 10.228989
    Rate of Left Arm Pulser&trig for electronic DT  = 10.159032
    Rate of Right Arm Pulser&trig for electronic DT  = 10.228989
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 14868.492
    Rate of Right Arm Strobe  = 7921.852
        Signal     |    Charge   (C)   
       upstream    |    0.0094910     
       upstream 3x |    0.0095419     
       upstream 10x|    0.0095650     
      downstream   |    0.0095783   
     downstream 3x |    -0.0000074   
     downstream 10x|    0.0096055    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3678 at Thu Apr 19 04:56:29 EDT 2001
    Right Arm D1 momentum                    : 1.35927
    Right Arm arm angle                      : 56.9814
    Left Arm D1 momentum                      : 3.44761
    Left Arm arm angle                        : 19.2802
    Tiefenbach Hall A energy                : 4000.27
    Right Arm arm mispointing (HPT)          : 2.43368
    Left Arm arm mispointing (HPT)            : 4.15399
    Right Arm Q1 power supply current        : 1022.17
    Right Arm Q1 momentum                    : 1.35939
    Right Arm Q1 gauss meter                 : -0.02553
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 584.808
    Right Arm Q2 momentum                    : 1.35886
    Right Arm Q2 gauss meter                 : 0.3075
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 464.108
    Right Arm D1 momentum                    : 1.35928
    Right Arm D1 NMR                         : 0.504411
    Right Arm Q3 power supply current        : 540.862
    Right Arm Q3 momentum                    : 1.35926
    Right Arm Q3 gauss meter                 : 0.2424
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2593.92
    Left Arm Q1 momentum                      : 3.44784
    Left Arm Q1 gauss meter                   : 0.21978
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1484.74
    Left Arm Q2 momentum                      : 3.44808
    Left Arm Q2 gauss meter                   : -0.7809
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1230.83
    Left Arm D1 momentum                      : 3.44761
    Left Arm D1 NMR                           : 1.27693
    Left Arm Q3 power supply current          : 1372.58
    Left Arm Q3 momentum                      : 3.44767
    Left Arm Q3 gauss meter                   : 0.6849
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.2202
    Current on Unser monitor                : 37.4771
    Current on Upstream bcm                 : 29.1276
    Current on Downstream bcm               : 29.3128
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.4308
    MBSY1c Hall A Beam energy               : 4007.97
    MBSY1c magnet current (amp)             : 167.035
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2422.92
    Tiefenbach Hall A energy                : 4000.27
    Tiefenbach Hall C energy                : 2416.8
    Delta(E)/E width (MV_AI_DXWID)          : 5.87462
    IPM1C12.XPOS                            : 0.00929496
    IPM1H04A.XPOS                           : 1.47647
    IPM1H04A.YPOS                           : 0.661648
    IPM1H04B.XPOS                           : 0.930132
    IPM1H04B.YPOS                           : 0.00687308
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4776
     HacR_VPM_LVDT:VALr                     : 635
     HacR_HPE1313A:0_Ch58                   : -0.514648
     HacR_HPE1313A:0_Ch55                   : 22.5586
     HacR_HPE1313A:0_Ch54                   : -0.804688
     HacR_alignROLL                         : -0.324912
     HacR_alignPITCH                        : -0.0379402
     HacR_alignHPT                          : 2.43308
     HacL_HPM_LVDT:VALr                     : -7168
     HacL_VPM_LVDT:VALr                     : 2611
     HacL_HPE1313A:0_Ch58                   : -0.130859
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.0893555
     HacL_alignROLL                         : 0.255966
     HacL_alignPITCH                        : -0.148085
     HacL_alignHPT                          : 4.15221
    haBDSPOS                                 : 1.70075e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66.5
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 19.28
    haH2_P_Exhaust_R                         : 19.66
    haH2_P_Fill_Bottle_R                     : 19.31
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 17.75
    haD2_P_Fill_Bottle_R                     : 36.67
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 241.68
    haSC200_6_Sensor_2_R                     : 26.82
    haSC200_6_Sensor_3_R                     : 43.31
    haSC200_6_Sensor_4_R                     : 41.72
    haHe_Omega_DPG_Sensor_R                  : 
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 82.65
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 88.9
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 0
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 0
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 87.62
    haITC502_6_Sensor_3_R                    : 28.61
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 36.5716
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 811.44
    Wien field                               : 23.657
    Laser attenuation Hall A                 : 166
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF