User name adev
Log entry time 05:50:08 on April 19, 2001
Entry number 60770
keyword=End_of_Run_3680
****************************
Run Number: 3680
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=ep_scan,mode=coincidence,Lmom=3.4476,Rmom=1.3593,Ene=3995,Angle_R=56.981,Angle_L=19.28
Time of run = 35.118408 min
Av. current (on 3x) = 31.504323 uA
Av. current (on 1x) = 63.012632 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 132.7742 | 66.3829 | 129.2190
up-down (mC)| -1.3432 | 132.8609 | -2.0745
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 95.979103 Hz | 3046.5 /mC | 47.990 Hz | 202238 | 2 | 1523.2 /mC
2 | 20696.828 Hz | 656952.0 /mC | 49.872 Hz | 43610380 | 415 | 328455.2 /mC
3 | 489.77827 Hz | 15546.4 /mC | 48.978 Hz | 1032014 | 10 | 7772.7 /mC
4 | 40083.996 Hz | 1272333.2 /mC | 49.794 Hz | 84461169 | 805 | 636126.4 /mC
5 | 12.724571 Hz | 403.9 /mC | 12.725 Hz | 26812 | 1 | 201.9 /mC
Trigger 5 corrected for pulser:
5 (phys) | 2.555166 Hz | 81.1 /mC | 2.555 Hz | 5384.001 | 1 | 40.6 /mC
8 | 1024.0 Hz | 32503.5 /mC | 0.016 Hz | 2157675 | 65535 | 16250.7 /mC
output 197.275 Hz
Av. deadtime from accepted triggers = 0.0221
Av. deadtime from gated scalers = 0.0279
Accepted triggers = 415678.00000
Rate of Left Arm Pulser for electronic DT = 10.169405
Rate of Right Arm Pulser for electronic DT = 10.182219
Rate of Left Arm Pulser&trig for electronic DT = 10.169405
Rate of Right Arm Pulser&trig for electronic DT = 10.182219
Left Arm Electronic DT = 0.0
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 56181.243
Rate of Right Arm Strobe = 21533.682
Signal | Charge (C)
upstream | 0.1321026
upstream 3x | 0.1328133
upstream 10x| 0.1281817
downstream | 0.1334458
downstream 3x | -0.0000476
downstream 10x| 0.1302562
****************************
End-of-run EPICS data for Run Number 3680 at Thu Apr 19 05:49:58 EDT 2001
Right Arm D1 momentum : 1.3593
Right Arm arm angle : 56.9812
Left Arm D1 momentum : 3.44761
Left Arm arm angle : 19.2801
Tiefenbach Hall A energy : 4000.26
Right Arm arm mispointing (HPT) : 2.45861
Left Arm arm mispointing (HPT) : 4.16705
Right Arm Q1 power supply current : 1022.17
Right Arm Q1 momentum : 1.35925
Right Arm Q1 gauss meter : -0.02551
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 584.741
Right Arm Q2 momentum : 1.3587
Right Arm Q2 gauss meter : 0.3075
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 464.515
Right Arm D1 momentum : 1.3593
Right Arm D1 NMR : 0.50442
Right Arm Q3 power supply current : 540.787
Right Arm Q3 momentum : 1.35907
Right Arm Q3 gauss meter : 0.2425
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2593.96
Left Arm Q1 momentum : 3.44789
Left Arm Q1 gauss meter : 0.21976
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1484.69
Left Arm Q2 momentum : 3.44795
Left Arm Q2 gauss meter : -0.7809
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1230.81
Left Arm D1 momentum : 3.44761
Left Arm D1 NMR : 1.27693
Left Arm Q3 power supply current : 1372.67
Left Arm Q3 momentum : 3.4479
Left Arm Q3 gauss meter : 0.6849
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 67.3511
Current on Unser monitor : 75.3545
Current on Upstream bcm : 67.3692
Current on Downstream bcm : 67.333
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 68.2986
MBSY1c Hall A Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
MBSY1c Bdl : 1.00019e+06
MBSY3c Hall C Beam energy : 2422.92
Tiefenbach Hall A energy : 4000.26
Tiefenbach Hall C energy : 2416.8
Delta(E)/E width (MV_AI_DXWID) : 5.87462
IPM1C12.XPOS : -0.00792974
IPM1H04A.XPOS : 1.46517
IPM1H04A.YPOS : 0.669858
IPM1H04B.XPOS : 0.920817
IPM1H04B.YPOS : 0.0377148
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4797
HacR_VPM_LVDT:VALr : 613
HacR_HPE1313A:0_Ch58 : -0.512695
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.808594
HacR_alignROLL : -0.327695
HacR_alignPITCH : -0.0403855
HacR_alignHPT : 2.45857
HacL_HPM_LVDT:VALr : -7178
HacL_VPM_LVDT:VALr : 2583
HacL_HPE1313A:0_Ch58 : -0.129883
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.090332
HacL_alignROLL : 0.255307
HacL_alignPITCH : -0.149264
HacL_alignHPT : 4.16705
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 19.24
haH2_P_Exhaust_R : 19.62
haH2_P_Fill_Bottle_R : 19.27
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 17.71
haD2_P_Fill_Bottle_R : 36.63
haD2_DP_Fill_Exhaust_R : 0.0742
haSC200_6_Sensor_1_R : 242.13
haSC200_6_Sensor_2_R : 27
haSC200_6_Sensor_3_R : 43.52
haSC200_6_Sensor_4_R : 41.87
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.44
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.18
haITC502_4_Sensor_1_R : 88.9
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 98.89
haITC502_5_Sensor_3_R : 969.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.58
haITC502_6_Sensor_3_R : 28.71
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616992
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 270
Laser power Hall A : 57
Half-wave plate (off=out) : OFF