User name adev
Log entry time 14:06:54 on April 19, 2001
Entry number 60813
keyword=Start_Run_3697_RunType=Optics,Tar=9foil-12C,Rad=out,comment=ep_scan,mode=singles,Lmom=2.377,Rmom=2.377,Ene=3995,Angle_R=32.841,Angle_L=32.762
Beginning-of-run EPICS data for Run Number 3697 at Thu Apr 19 14:06:42 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=5,ps2=250,ps3=1,ps4=250,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1787.38
Right Arm Q1 momentum : 2.37704
Right Arm Q1 gauss meter : 0.04465
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1022.89
Right Arm Q2 momentum : 2.37678
Right Arm Q2 gauss meter : -0.5382
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 835.45
Right Arm D1 momentum : 2.377
Right Arm D1 NMR : 0.882076
Right Arm Q3 power supply current : 945.853
Right Arm Q3 momentum : 2.37724
Right Arm Q3 gauss meter : -0.4241
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1788.19
Left Arm Q1 momentum : 2.37686
Left Arm Q1 gauss meter : -0.15118
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1023.32
Left Arm Q2 momentum : 2.3765
Left Arm Q2 gauss meter : 0.5397
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 815.734
Left Arm D1 momentum : 2.37701
Left Arm D1 NMR : 0.879673
Left Arm Q3 power supply current : 946.317
Left Arm Q3 momentum : 2.37697
Left Arm Q3 gauss meter : -0.4721
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 30.157
Current on Unser monitor : 37.4667
Current on Upstream bcm : 30.2451
Current on Downstream bcm : 30.0689
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 75.9061
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.03541
Radiator Encoder : 0.163614
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.83
haSC200_6_Sensor_2_R : 26.77
haSC200_6_Sensor_3_R : 43.37
haSC200_6_Sensor_4_R : 41.84
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.22
haITC502_4_Sensor_1_R : 88.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.91
haITC502_5_Sensor_2_R : 0.06
haITC502_5_Sensor_3_R : 0.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.27
haITC502_6_Sensor_3_R : 28.57
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -909
HacR_VPM_LVDT:VALr : 510
HacR_HPE1313A:0_Ch58 : -0.532715
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.821289
HacR_alignROLL : -0.340136
HacR_alignPITCH : -0.0222969
HacR_alignHPT : -1.7954
HacL_HPM_LVDT:VALr : -8363
HacL_VPM_LVDT:VALr : 871
HacL_HPE1313A:0_Ch58 : -0.16748
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.269043
HacL_alignROLL : 0.0942861
HacL_alignPITCH : -0.0951186
HacL_alignHPT : 5.57888
Right Arm Angle Floor Angle : 32.5
Right Arm Angle Vernier : 23
Right Arm Scattering Angle : 32.8417
Left Arm Angle Floor Angle : 33
Left Arm Angle Vernier : -3.6
Left Arm Scattering Angle : 32.7625
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 229
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88