    User name adev

    Log entry time 14:16:42 on April 19, 2001

    Entry number 60814

    keyword=End_of_Run_3697
    ****************************
     Run Number: 3697
    End of Run Comment:
    RunType=Optics,Tar=9foil-12C,Rad=out,comment=ep_scan,mode=singles,Lmom=2.377,Rmom=2.377,Ene=3995,Angle_R=32.841,Angle_L=32.762
    
    Time of run = 10.745996 min
    Av. current (on 3x) = 17.421217 uA
    Av. current (on 1x) = 34.843985 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   22.4660  |   11.2325  |   22.1072
    up-down    (mC)|   -0.2103  |   22.4941  |   -0.2751
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 120.21842 Hz  |      6900.7 /mC  |   24.044 Hz  |     77512  |     5   |      3450.2 /mC
        2      | 6940.9712 Hz  |    398420.6 /mC  |   27.764 Hz  |   4475259  |   250   |    199201.4 /mC
        3      | 42.074585 Hz  |      2415.1 /mC  |   42.075 Hz  |     27128  |     1   |      1207.5 /mC
        4      | 6251.6183 Hz  |    358850.8 /mC  |   25.006 Hz  |   4030792  |   250   |    179417.4 /mC
        5      | 10.517095 Hz  |       603.7 /mC  |   10.517 Hz  |      6781  |     1   |       301.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.356722 Hz  |        20.5 /mC  |    0.357 Hz  | 230.00024  |     1   |        10.2 /mC
        8    | 1024.0 Hz  |     58778.9 /mC  |    0.016 Hz  |    660234  | 65535   |     29388.1 /mC
        output                       114.581 Hz
    Av. deadtime from accepted triggers = 0.0190
    Av. deadtime from gated scalers = 0.0231
    Accepted triggers  =  73877.00000
    Rate of Left Arm Pulser for electronic DT  = 10.160373
    Rate of Right Arm Pulser for electronic DT  = 10.206902
    Rate of Left Arm Pulser&trig for electronic DT  = 10.160373
    Rate of Right Arm Pulser&trig for electronic DT  = 10.206902
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 9041.1255
    Rate of Right Arm Strobe  = 7295.1279
        Signal     |    Charge   (C)   
       upstream    |    0.0223609     
       upstream 3x |    0.0224795     
       upstream 10x|    0.0219696     
      downstream   |    0.0225712   
     downstream 3x |    -0.0000146   
     downstream 10x|    0.0222447    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3697 at Thu Apr 19 14:16:31 EDT 2001
    Right Arm D1 momentum                    : 2.377
    Right Arm arm angle                      : 32.8417
    Left Arm D1 momentum                      : 2.37701
    Left Arm arm angle                        : 32.7624
    Tiefenbach Hall A energy                : 4000.31
    Right Arm arm mispointing (HPT)          : -1.78567
    Left Arm arm mispointing (HPT)            : 5.58973
    Right Arm Q1 power supply current        : 1787.38
    Right Arm Q1 momentum                    : 2.37704
    Right Arm Q1 gauss meter                 : 0.04464
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1022.78
    Right Arm Q2 momentum                    : 2.37653
    Right Arm Q2 gauss meter                 : -0.5382
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 835.443
    Right Arm D1 momentum                    : 2.377
    Right Arm D1 NMR                         : 0.882076
    Right Arm Q3 power supply current        : 945.711
    Right Arm Q3 momentum                    : 2.3767
    Right Arm Q3 gauss meter                 : -0.4242
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1788.19
    Left Arm Q1 momentum                      : 2.37686
    Left Arm Q1 gauss meter                   : -0.15118
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1023.54
    Left Arm Q2 momentum                      : 2.37702
    Left Arm Q2 gauss meter                   : 0.5397
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 815.729
    Left Arm D1 momentum                      : 2.37701
    Left Arm D1 NMR                           : 0.879673
    Left Arm Q3 power supply current          : 946.302
    Left Arm Q3 momentum                      : 2.37693
    Left Arm Q3 gauss meter                   : -0.4721
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 67.8824
    Current on Unser monitor                : 74.677
    Current on Upstream bcm                 : 67.8499
    Current on Downstream bcm               : 67.915
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 109.667
    MBSY1c Hall A Beam energy               : 4007.97
    MBSY1c magnet current (amp)             : 167.035
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2422.92
    Tiefenbach Hall A energy                : 4000.33
    Tiefenbach Hall C energy                : 2418.41
    Delta(E)/E width (MV_AI_DXWID)          : 3.69343
    IPM1C12.XPOS                            : -0.00277579
    IPM1H04A.XPOS                           : -0.182056
    IPM1H04A.YPOS                           : 0.272243
    IPM1H04B.XPOS                           : -0.0591856
    IPM1H04B.YPOS                           : -0.129771
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -919
     HacR_VPM_LVDT:VALr                     : 511
     HacR_HPE1313A:0_Ch58                   : -0.531738
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.819336
     HacR_alignROLL                         : -0.339034
     HacR_alignPITCH                        : -0.0233278
     HacR_alignHPT                          : -1.78483
     HacL_HPM_LVDT:VALr                     : -8370
     HacL_VPM_LVDT:VALr                     : 862
     HacL_HPE1313A:0_Ch58                   : -0.166016
     HacL_HPE1313A:0_Ch55                   : 23.7305
     HacL_HPE1313A:0_Ch54                   : -0.267578
     HacL_alignROLL                         : 0.0954527
     HacL_alignPITCH                        : -0.0967232
     HacL_alignHPT                          : 5.58725
    haBDSPOS                                 : 2.47884e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 64
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 21.41
    haH2_P_Exhaust_R                         : 21.74
    haH2_P_Fill_Bottle_R                     : 21.42
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 19.14
    haD2_P_Fill_Bottle_R                     : 39.53
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 242.11
    haSC200_6_Sensor_2_R                     : 26.85
    haSC200_6_Sensor_3_R                     : 43.54
    haSC200_6_Sensor_4_R                     : 41.87
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 82.31
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 18.99
    haITC502_4_Sensor_1_R                    : 88.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 322.13
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 982.6
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 87.26
    haITC502_6_Sensor_3_R                    : 28.57
    Right Arm Arm Collimator                 : 0.614893
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 36.5716
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 811.44
    Wien field                               : 23.657
    Laser attenuation Hall A                 : 279
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF