User name adev
Log entry time 14:26:12 on April 19, 2001
Entry number 60815
keyword=Start_Run_3698_RunType=Optics,Tar=9foil-12C,Rad=out,comment=ep_scan,mode=singles,Lmom=2.377,Rmom=2.377,Ene=3995,Angle_R=32.841,Angle_L=32.762
Beginning-of-run EPICS data for Run Number 3698 at Thu Apr 19 14:26:01 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=650,ps3=7,ps4=600,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1787.38
Right Arm Q1 momentum : 2.37704
Right Arm Q1 gauss meter : 0.04464
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1022.86
Right Arm Q2 momentum : 2.37672
Right Arm Q2 gauss meter : -0.5381
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 835.436
Right Arm D1 momentum : 2.377
Right Arm D1 NMR : 0.882076
Right Arm Q3 power supply current : 945.672
Right Arm Q3 momentum : 2.37661
Right Arm Q3 gauss meter : -0.4242
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1788.29
Left Arm Q1 momentum : 2.377
Left Arm Q1 gauss meter : -0.1512
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1023.38
Left Arm Q2 momentum : 2.37665
Left Arm Q2 gauss meter : 0.5396
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 815.722
Left Arm D1 momentum : 2.37701
Left Arm D1 NMR : 0.879672
Left Arm Q3 power supply current : 946.321
Left Arm Q3 momentum : 2.37698
Left Arm Q3 gauss meter : -0.4721
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 67.5464
Current on Unser monitor : 76.1601
Current on Upstream bcm : 67.4576
Current on Downstream bcm : 67.6353
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 120.633
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.02808
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.3
haSC200_6_Sensor_2_R : 26.9
haSC200_6_Sensor_3_R : 43.62
haSC200_6_Sensor_4_R : 41.89
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.2
haITC502_4_Sensor_1_R : 88.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 39.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.29
haITC502_6_Sensor_3_R : 28.77
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -921
HacR_VPM_LVDT:VALr : 503
HacR_HPE1313A:0_Ch58 : -0.531738
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.820312
HacR_alignROLL : -0.339527
HacR_alignPITCH : -0.0233278
HacR_alignHPT : -1.78231
HacL_HPM_LVDT:VALr : -8382
HacL_VPM_LVDT:VALr : 855
HacL_HPE1313A:0_Ch58 : -0.166016
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.269531
HacL_alignROLL : 0.0942688
HacL_alignPITCH : -0.0973073
HacL_alignHPT : 5.60123
Right Arm Angle Floor Angle : 32.5
Right Arm Angle Vernier : 23
Right Arm Scattering Angle : 32.8416
Left Arm Angle Floor Angle : 33
Left Arm Angle Vernier : -3.6
Left Arm Scattering Angle : 32.7623
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 282
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88