User name adev
Log entry time 21:17:27 on April 19, 2001
Entry number 60846
keyword=Start_Run_3709_RunType=Optics,Tar=9foil-12C,Rad=out,comment=Elastic
Beginning-of-run EPICS data for Run Number 3709 at Thu Apr 19 21:17:17 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=800,ps3=1,ps4=500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1283.8
Right Arm Q1 momentum : 1.70733
Right Arm Q1 gauss meter : 0.0322
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 734.882
Right Arm Q2 momentum : 1.70757
Right Arm Q2 gauss meter : -0.3869
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 586.02
Right Arm D1 momentum : 1.70728
Right Arm D1 NMR : 0.63355
Right Arm Q3 power supply current : 679.238
Right Arm Q3 momentum : 1.70702
Right Arm Q3 gauss meter : -0.3049
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2245.22
Left Arm Q1 momentum : 2.98434
Left Arm Q1 gauss meter : -0.18982
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1285.2
Left Arm Q2 momentum : 2.98468
Left Arm Q2 gauss meter : 0.6771
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1043.95
Left Arm D1 momentum : 2.98421
Left Arm D1 NMR : 1.10498
Left Arm Q3 power supply current : 1187.96
Left Arm Q3 momentum : 2.98394
Left Arm Q3 gauss meter : -0.5928
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 68.0101
Current on Unser monitor : 75.3721
Current on Upstream bcm : 67.7949
Current on Downstream bcm : 68.2253
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 118.314
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.166056
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.23
haSC200_6_Sensor_2_R : 26.92
haSC200_6_Sensor_3_R : 43.69
haSC200_6_Sensor_4_R : 41.84
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.08
haITC502_4_Sensor_1_R : 88.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 98.37
haITC502_5_Sensor_3_R : 960.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.27
haITC502_6_Sensor_3_R : 28.55
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4552
HacR_VPM_LVDT:VALr : 510
HacR_HPE1313A:0_Ch58 : -0.535645
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.913574
HacR_alignROLL : -0.43363
HacR_alignPITCH : -0.0193543
HacR_alignHPT : 2.31037
HacL_HPM_LVDT:VALr : -6628
HacL_VPM_LVDT:VALr : 2076
HacL_HPE1313A:0_Ch58 : -0.136719
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.174805
HacL_alignROLL : 0.179393
HacL_alignPITCH : -0.12205
HacL_alignHPT : 3.58783
Right Arm Angle Floor Angle : 43
Right Arm Angle Vernier : -20.3
Right Arm Scattering Angle : 43.0643
Left Arm Angle Floor Angle : 23
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 22.976
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 287
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88