User name adev
Log entry time 22:02:29 on April 19, 2001
Entry number 60851
keyword=Start_Run_3710_RunType=Elastic,Tar=LD2-15cm,Rad=out,comment=Elastic
Beginning-of-run EPICS data for Run Number 3710 at Thu Apr 19 22:02:17 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=15,ps2=540,ps3=80,ps4=800,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1283.77
Right Arm Q1 momentum : 1.70728
Right Arm Q1 gauss meter : 0.03219
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 734.751
Right Arm Q2 momentum : 1.70726
Right Arm Q2 gauss meter : -0.3869
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 586.378
Right Arm D1 momentum : 1.7073
Right Arm D1 NMR : 0.633559
Right Arm Q3 power supply current : 679.122
Right Arm Q3 momentum : 1.70673
Right Arm Q3 gauss meter : -0.3048
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2245.18
Left Arm Q1 momentum : 2.9843
Left Arm Q1 gauss meter : -0.18986
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1285
Left Arm Q2 momentum : 2.98421
Left Arm Q2 gauss meter : 0.677
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1043.96
Left Arm D1 momentum : 2.98421
Left Arm D1 NMR : 1.10498
Left Arm Q3 power supply current : 1188.12
Left Arm Q3 momentum : 2.98434
Left Arm Q3 gauss meter : -0.5928
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.49607
Current on Unser monitor : 10.9552
Current on Upstream bcm : 4.5205
Current on Downstream bcm : 4.47165
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 63.0924
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.02808
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.63
haSC200_6_Sensor_2_R : 26.73
haSC200_6_Sensor_3_R : 43.36
haSC200_6_Sensor_4_R : 41.67
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.14
haITC502_4_Sensor_1_R : 88.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.5
haITC502_5_Sensor_2_R : 0.06
haITC502_5_Sensor_3_R : 0.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.31
haITC502_6_Sensor_3_R : 28.73
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4530
HacR_VPM_LVDT:VALr : 522
HacR_HPE1313A:0_Ch58 : -0.537109
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.918457
HacR_alignROLL : -0.437796
HacR_alignPITCH : -0.0190883
HacR_alignHPT : 2.28812
HacL_HPM_LVDT:VALr : -6616
HacL_VPM_LVDT:VALr : 2092
HacL_HPE1313A:0_Ch58 : -0.138672
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.17627
HacL_alignROLL : 0.178291
HacL_alignPITCH : -0.120954
HacL_alignHPT : 3.57383
Right Arm Angle Floor Angle : 43
Right Arm Angle Vernier : -20.3
Right Arm Scattering Angle : 43.0645
Left Arm Angle Floor Angle : 23
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 22.976
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 220
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88