Log entry time 06:34:18 on April 20, 2001
Entry number 60903
keyword=Start_Run_3734_RunType=Other,Tar=LD2-15cm,Rad=out,comment=Cerenkov
Beginning-of-run EPICS data for Run Number 3734 at Fri Apr 20 06:34:00 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=550,ps3=60,ps4=65535,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1879.78
Right Arm Q1 momentum : 2.49992
Right Arm Q1 gauss meter : -0.04674
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1075.73
Right Arm Q2 momentum : 2.49956
Right Arm Q2 gauss meter : 0.5644
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 882.283
Right Arm D1 momentum : 2.5
Right Arm D1 NMR : 0.92772
Right Arm Q3 power supply current : 994.732
Right Arm Q3 momentum : 2.4999
Right Arm Q3 gauss meter : 0.4457
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 752.01
Left Arm Q1 momentum : 0.999573
Left Arm Q1 gauss meter : -0.06367
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 430.502
Left Arm Q2 momentum : 0.999774
Left Arm Q2 gauss meter : 0.2275
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 333.582
Left Arm D1 momentum : 1.00001
Left Arm D1 NMR : 0.370233
Left Arm Q3 power supply current : 398.099
Left Arm Q3 momentum : 0.99995
Left Arm Q3 gauss meter : -0.19863
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 28.9879
Current on Unser monitor : 36.0424
Current on Upstream bcm : 28.7923
Current on Downstream bcm : 29.1834
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 79.5851
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.161172
haBDSPOS : 3.07567e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 27
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 241.56
haSC200_6_Sensor_2_R : 26.66
haSC200_6_Sensor_3_R : 43.4
haSC200_6_Sensor_4_R : 41.76
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.64
haITC502_4_Sensor_1_R : 88.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 26.61
haITC502_5_Sensor_2_R : 321.62
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.44
haITC502_6_Sensor_3_R : 28.48
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868604
HacR_HPM_LVDT:VALr : -762
HacR_VPM_LVDT:VALr : 306
HacR_HPE1313A:0_Ch58 : -0.537598
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.769531
HacR_alignROLL : -0.288435
HacR_alignPITCH : -0.0177418
HacR_alignHPT : -1.99053
HacL_HPM_LVDT:VALr : -7496
HacL_VPM_LVDT:VALr : 1064
HacL_HPE1313A:0_Ch58 : -0.157715
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.259277
HacL_alignROLL : 0.102167
HacL_alignPITCH : -0.103777
HacL_alignHPT : 4.60746
Right Arm Angle Floor Angle : 30
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 30.2105
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 29.7898
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 182
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88