User name adev
Log entry time 00:58:09 on April 22, 2001
Entry number 60973
keyword=Start_Run_3769_RunType=Other,Tar=9foil-12C,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3769 at Sun Apr 22 00:57:59 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=20,ps2=1,ps3=20,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 800.87
Right Arm Q1 momentum : 1.06508
Right Arm Q1 gauss meter : -0.020025
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 458.495
Right Arm Q2 momentum : 1.06536
Right Arm Q2 gauss meter : 0.241
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 364.12
Right Arm D1 momentum : 1.065
Right Arm D1 NMR : 0.395209
Right Arm Q3 power supply current : 423.727
Right Arm Q3 momentum : 1.06488
Right Arm Q3 gauss meter : 0.18985
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 800.905
Left Arm Q1 momentum : 1.06456
Left Arm Q1 gauss meter : -0.06776
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 458.541
Left Arm Q2 momentum : 1.06489
Left Arm Q2 gauss meter : 0.2423
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 355.216
Left Arm D1 momentum : 1.06499
Left Arm D1 NMR : 0.394274
Left Arm Q3 power supply current : 424.057
Left Arm Q3 momentum : 1.06515
Left Arm Q3 gauss meter : -0.2114
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 94.1528
Current on Unser monitor : 102.261
Current on Upstream bcm : 94.2673
Current on Downstream bcm : 94.0383
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 153.12
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.163614
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.51
haSC200_6_Sensor_2_R : 24.52
haSC200_6_Sensor_3_R : 43.44
haSC200_6_Sensor_4_R : 41.58
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 74.22
haITC502_1_Sensor_2_R : 74.11
haITC502_1_Sensor_3_R : 78.03
haITC502_4_Sensor_1_R : 85.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 730.7
haITC502_6_Sensor_1_R : 75.18
haITC502_6_Sensor_2_R : 76.92
haITC502_6_Sensor_3_R : 28.54
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4923
HacR_VPM_LVDT:VALr : 644
HacR_HPE1313A:0_Ch58 : -0.524414
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.895996
HacR_alignROLL : -0.415558
HacR_alignPITCH : -0.0299276
HacR_alignHPT : 2.68662
HacL_HPM_LVDT:VALr : -8815
HacL_VPM_LVDT:VALr : -309
HacL_HPE1313A:0_Ch58 : -0.254395
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.33252
HacL_alignROLL : 0.0372311
HacL_alignPITCH : -0.016455
HacL_alignHPT : 6.09861
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 44.9799
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 30.5
Left Arm Scattering Angle : 44.9555
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 345
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88