    User name adev

    Log entry time 01:51:32 on April 22, 2001

    Entry number 60979

    keyword=End_of_Run_3771
    ****************************
     Run Number: 3771
    End of Run Comment:
    RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White Scan,mode=singles,Lmom=1.065,Rmom=1.065,Ene=3994,Angle_R=45,Angle_L=45
    
    
    Time of run = 20.545622 min
    Av. current (on 3x) = 37.694649 uA
    Av. current (on 1x) = 75.330567 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   92.8628  |   46.4676  |   79.0500
    up-down    (mC)|   -0.7627  |   92.9907  |   -2.0604
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 4502.9342 Hz  |    119458.2 /mC  |  281.433 Hz  |   5550935  |    16   |     59775.7 /mC
        2      | 283.61274 Hz  |      7524.0 /mC  |  283.613 Hz  |    349620  |     1   |      3764.9 /mC
        3      | 4324.1565 Hz  |    114715.4 /mC  |  270.260 Hz  |   5330549  |    16   |     57402.4 /mC
        4      | 314.97141 Hz  |      8355.9 /mC  |  314.971 Hz  |    388277  |     1   |      4181.2 /mC
        5      | 2.1975485 Hz  |        58.3 /mC  |    0.000 Hz  |      2709  | 65535   |        29.2 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 2.1975485 Hz  |        58.3 /mC  |    0.000 Hz  | 2709.0  | 65535   |        29.2 /mC
        8    | 1024.0 Hz  |     27165.7 /mC  |    0.016 Hz  |   1262323  | 65535   |     13593.4 /mC
        output                       950.027 Hz
    Av. deadtime from accepted triggers = 0.1741
    Av. deadtime from gated scalers = 0.1561
    Accepted triggers  = 1171134.00000
    Rate of Left Arm Pulser for electronic DT  = 0.0
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 0.0
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = -1
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 42351.226
    Rate of Right Arm Strobe  = 34550.931
        Signal     |    Charge   (C)   
       upstream    |    0.0924815     
       upstream 3x |    0.0929629     
       upstream 10x|    0.0780198     
      downstream   |    0.0932442   
     downstream 3x |    -0.0000278   
     downstream 10x|    0.0800802    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3771 at Sun Apr 22 01:51:20 EDT 2001
    Right Arm D1 momentum                    : 1.065
    Right Arm arm angle                      : 44.98
    Left Arm D1 momentum                      : 1.06499
    Left Arm arm angle                        : 44.9554
    Tiefenbach Hall A energy                : 4000.33
    Right Arm arm mispointing (HPT)          : 2.68138
    Left Arm arm mispointing (HPT)            : 6.10737
    Right Arm Q1 power supply current        : 800.87
    Right Arm Q1 momentum                    : 1.06508
    Right Arm Q1 gauss meter                 : -0.020021
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 458.359
    Right Arm Q2 momentum                    : 1.06504
    Right Arm Q2 gauss meter                 : 0.2409
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 364.112
    Right Arm D1 momentum                    : 1.065
    Right Arm D1 NMR                         : 0.395208
    Right Arm Q3 power supply current        : 424.014
    Right Arm Q3 momentum                    : 1.0656
    Right Arm Q3 gauss meter                 : 0.18991
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 800.87
    Left Arm Q1 momentum                      : 1.06452
    Left Arm Q1 gauss meter                   : -0.06776
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 458.491
    Left Arm Q2 momentum                      : 1.06477
    Left Arm Q2 gauss meter                   : 0.2423
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 355.217
    Left Arm D1 momentum                      : 1.06499
    Left Arm D1 NMR                           : 0.394274
    Left Arm Q3 power supply current          : 423.981
    Left Arm Q3 momentum                      : 1.06496
    Left Arm Q3 gauss meter                   : -0.2114
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 93.9611
    Current on Unser monitor                : 100.933
    Current on Upstream bcm                 : 93.9665
    Current on Downstream bcm               : 93.9556
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 151.805
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2422.92
    Tiefenbach Hall A energy                : 4000.33
    Tiefenbach Hall C energy                : 2418.38
    Delta(E)/E width (MV_AI_DXWID)          : 2.71799
    IPM1C12.XPOS                            : 0.000255048
    IPM1H04A.XPOS                           : 1.12335
    IPM1H04A.YPOS                           : 0.495194
    IPM1H04B.XPOS                           : 1.01836
    IPM1H04B.YPOS                           : 0.0155228
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616895
     HacR_HPM_LVDT:VALr                     : -4918
     HacR_VPM_LVDT:VALr                     : 658
     HacR_HPE1313A:0_Ch58                   : -0.524414
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.895996
     HacR_alignROLL                         : -0.415502
     HacR_alignPITCH                        : -0.0308921
     HacR_alignHPT                          : 2.68103
     HacL_HPM_LVDT:VALr                     : -8825
     HacL_VPM_LVDT:VALr                     : -318
     HacL_HPE1313A:0_Ch58                   : -0.254395
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.331055
     HacL_alignROLL                         : 0.0376035
     HacL_alignPITCH                        : -0.0176931
     HacL_alignHPT                          : 6.10848
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 69
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 20.51
    haH2_P_Exhaust_R                         : 20.89
    haH2_P_Fill_Bottle_R                     : 20.47
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.84
    haD2_P_Fill_Bottle_R                     : 38.8
    haD2_DP_Fill_Exhaust_R                   : 0.0749
    haSC200_6_Sensor_1_R                     : 241.53
    haSC200_6_Sensor_2_R                     : 26.33
    haSC200_6_Sensor_3_R                     : 43.47
    haSC200_6_Sensor_4_R                     : 41.64
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 87.95
    haITC502_1_Sensor_2_R                    : 87.01
    haITC502_1_Sensor_3_R                    : 90.87
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.23
    haITC502_4_Sensor_1_R                    : 94.5
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 0.05
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 39.9
    haITC502_6_Sensor_1_R                    : 85.94
    haITC502_6_Sensor_2_R                    : 86.8
    haITC502_6_Sensor_3_R                    : 28.58
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 342
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF