User name adev
Log entry time 05:46:55 on April 22, 2001
Entry number 60992
keyword=Start_Run_3778_RunType=Other,Tar=9foil-12C,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3778 at Sun Apr 22 05:46:42 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 738.605
Right Arm Q1 momentum : 0.982273
Right Arm Q1 gauss meter : -0.018497
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 422.589
Right Arm Q2 momentum : 0.981926
Right Arm Q2 gauss meter : 0.2222
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 335.062
Right Arm D1 momentum : 0.982302
Right Arm D1 NMR : 0.36452
Right Arm Q3 power supply current : 390.84
Right Arm Q3 momentum : 0.982234
Right Arm Q3 gauss meter : 0.1751
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 738.605
Left Arm Q1 momentum : 0.981755
Left Arm Q1 gauss meter : -0.06255
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 422.968
Left Arm Q2 momentum : 0.982276
Left Arm Q2 gauss meter : 0.2235
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 327.207
Left Arm D1 momentum : 0.982298
Left Arm D1 NMR : 0.363681
Left Arm Q3 power supply current : 391.043
Left Arm Q3 momentum : 0.982228
Left Arm Q3 gauss meter : -0.19506
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 85.7058
Current on Unser monitor : 91.4431
Current on Upstream bcm : 85.4692
Current on Downstream bcm : 85.9424
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 143.483
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.163614
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.63
haSC200_6_Sensor_2_R : 30.22
haSC200_6_Sensor_3_R : 43.5
haSC200_6_Sensor_4_R : 41.59
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 113.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.86
haITC502_5_Sensor_2_R : 26.7
haITC502_5_Sensor_3_R : 0.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.14
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616895
HacR_HPM_LVDT:VALr : -4920
HacR_VPM_LVDT:VALr : 668
HacR_HPE1313A:0_Ch58 : -0.522949
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.898438
HacR_alignROLL : -0.418459
HacR_alignPITCH : -0.031341
HacR_alignHPT : 2.68605
HacL_HPM_LVDT:VALr : -8818
HacL_VPM_LVDT:VALr : -316
HacL_HPE1313A:0_Ch58 : -0.253418
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.330078
HacL_alignROLL : 0.0389287
HacL_alignPITCH : -0.0181297
HacL_alignHPT : 6.10114
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 44.98
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 30.5
Left Arm Scattering Angle : 44.9555
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 326
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88