Log entry time 07:55:24 on April 22, 2001
Entry number 61002
keyword=Start_Run_3783_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3783 at Sun Apr 22 07:55:14 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 769.02
Right Arm Q1 momentum : 1.02272
Right Arm Q1 gauss meter : -0.019252
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 440.25
Right Arm Q2 momentum : 1.02296
Right Arm Q2 gauss meter : 0.2314
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 347.644
Right Arm D1 momentum : 1.02277
Right Arm D1 NMR : 0.379537
Right Arm Q3 power supply current : 407.043
Right Arm Q3 momentum : 1.02296
Right Arm Q3 gauss meter : 0.1824
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 769.335
Left Arm Q1 momentum : 1.0226
Left Arm Q1 gauss meter : -0.06513
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 440.41
Left Arm Q2 momentum : 1.02271
Left Arm Q2 gauss meter : 0.2327
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 340.779
Left Arm D1 momentum : 1.02279
Left Arm D1 NMR : 0.378661
Left Arm Q3 power supply current : 407.169
Left Arm Q3 momentum : 1.02273
Left Arm Q3 gauss meter : -0.2029
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 86.5551
Current on Unser monitor : 93.8646
Current on Upstream bcm : 86.3301
Current on Downstream bcm : 86.7801
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 146.493
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.64
haSC200_6_Sensor_2_R : 31.58
haSC200_6_Sensor_3_R : 43.64
haSC200_6_Sensor_4_R : 41.74
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 119.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 3.99
haITC502_5_Sensor_3_R : 10
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.22
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -3531
HacR_VPM_LVDT:VALr : 777
HacR_HPE1313A:0_Ch58 : -0.51709
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.942383
HacR_alignROLL : -0.463429
HacR_alignPITCH : -0.0361448
HacR_alignHPT : 1.1602
HacL_HPM_LVDT:VALr : -6788
HacL_VPM_LVDT:VALr : -191
HacL_HPE1313A:0_Ch58 : -0.232422
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.28418
HacL_alignROLL : 0.0800093
HacL_alignPITCH : -0.0364669
HacL_alignHPT : 3.80984
Right Arm Angle Floor Angle : 43.5
Right Arm Angle Vernier : -17
Right Arm Scattering Angle : 43.5912
Left Arm Angle Floor Angle : 43.5
Left Arm Angle Vernier : 48.7
Left Arm Scattering Angle : 43.5759
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 325
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88