• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 08:15:48 on April 22, 2001

    Entry number 61005

    keyword=End_of_Run_3783
    ****************************
     Run Number: 3783
    End of Run Comment:
    RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White Scan,mode=singles,Lmom=1.0228,Rmom=1.0228,Ene=3994,Angle_R=43.6,Angle_L=43.6
    
    Time of run = 20.362288 min
    Av. current (on 3x) = 42.99484 uA
    Av. current (on 1x) = 85.976584 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  105.0408  |   52.5284  |   92.8226
    up-down    (mC)|   -1.0113  |  105.1120  |   -2.3115
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 8137.9532 Hz  |    189277.4 /mC  |  508.622 Hz  |   9942441  |    16   |     94653.1 /mC
        2      | 449.30281 Hz  |     10450.2 /mC  |  449.303 Hz  |    548930  |     1   |      5225.9 /mC
        3      | 7849.0384 Hz  |    182557.7 /mC  |  490.565 Hz  |   9589463  |    16   |     91292.7 /mC
        4      | 520.11099 Hz  |     12097.1 /mC  |  520.111 Hz  |    635439  |     1   |      6049.4 /mC
        5      | 5.8146706 Hz  |       135.2 /mC  |    0.000 Hz  |      7104  | 65535   |        67.6 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 5.8146706 Hz  |       135.2 /mC  |    0.000 Hz  | 7104.0  | 65535   |        67.6 /mC
        8    | 1024.0 Hz  |     23816.8 /mC  |    0.016 Hz  |   1251059  | 65535   |     11910.2 /mC
        output                      1539.991 Hz
    Av. deadtime from accepted triggers = 0.2177
    Av. deadtime from gated scalers = 0.2104
    Accepted triggers  = 1881464.00000
    Rate of Left Arm Pulser for electronic DT  = 0.0
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 0.0
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = -1
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 55160.038
    Rate of Right Arm Strobe  = 45906.087
        Signal     |    Charge   (C)   
       upstream    |    0.1045351     
       upstream 3x |    0.1050844     
       upstream 10x|    0.0916668     
      downstream   |    0.1055464   
     downstream 3x |    -0.0000276   
     downstream 10x|    0.0939783    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3783 at Sun Apr 22 08:15:39 EDT 2001
    Right Arm D1 momentum                    : 1.0228
    Right Arm arm angle                      : 43.5911
    Left Arm D1 momentum                      : 1.02279
    Left Arm arm angle                        : 43.5759
    Tiefenbach Hall A energy                : 4000.31
    Right Arm arm mispointing (HPT)          : 1.16657
    Left Arm arm mispointing (HPT)            : 3.81162
    Right Arm Q1 power supply current        : 768.985
    Right Arm Q1 momentum                    : 1.02268
    Right Arm Q1 gauss meter                 : -0.019239
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 440.008
    Right Arm Q2 momentum                    : 1.0224
    Right Arm Q2 gauss meter                 : 0.2315
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 349.192
    Right Arm D1 momentum                    : 1.0228
    Right Arm D1 NMR                         : 0.379549
    Right Arm Q3 power supply current        : 406.995
    Right Arm Q3 momentum                    : 1.0235
    Right Arm Q3 gauss meter                 : 0.18244
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 769.3
    Left Arm Q1 momentum                      : 1.02255
    Left Arm Q1 gauss meter                   : -0.06508
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 440.395
    Left Arm Q2 momentum                      : 1.02275
    Left Arm Q2 gauss meter                   : 0.2327
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 340.789
    Left Arm D1 momentum                      : 1.02279
    Left Arm D1 NMR                           : 0.378663
    Left Arm Q3 power supply current          : 407.204
    Left Arm Q3 momentum                      : 1.02282
    Left Arm Q3 gauss meter                   : -0.2029
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 1.70776e-304
    Current on Unser monitor                : 7.82962
    Current on Upstream bcm                 : 1.69517e-304
    Current on Downstream bcm               : 1.72036e-304
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 66.3265
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2422.92
    Tiefenbach Hall A energy                : 4000.33
    Tiefenbach Hall C energy                : 2418.52
    Delta(E)/E width (MV_AI_DXWID)          : 2.94652
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -3538
     HacR_VPM_LVDT:VALr                     : 781
     HacR_HPE1313A:0_Ch58                   : -0.51709
     HacR_HPE1313A:0_Ch55                   : 22.5098
     HacR_HPE1313A:0_Ch54                   : -0.942871
     HacR_alignROLL                         : -0.463429
     HacR_alignPITCH                        : -0.0365936
     HacR_alignHPT                          : 1.16691
     HacL_HPM_LVDT:VALr                     : -6788
     HacL_VPM_LVDT:VALr                     : -196
     HacL_HPE1313A:0_Ch58                   : -0.232422
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.28418
     HacL_alignROLL                         : 0.0809633
     HacL_alignPITCH                        : -0.0369757
     HacL_alignHPT                          : 3.81385
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66.9311
    haL3_Fan_frequency_R                     : 24.2935
    haH2_P_Fill_Target_R                     : 19.34
    haH2_P_Exhaust_R                         : 19.22
    haH2_P_Fill_Bottle_R                     : 19.37
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -880
    haD2_P_Exhaust_R                         : 18.79
    haD2_P_Fill_Bottle_R                     : 38.78
    haD2_DP_Fill_Exhaust_R                   : 0.0745
    haSC200_6_Sensor_1_R                     : 241.83
    haSC200_6_Sensor_2_R                     : 31.8
    haSC200_6_Sensor_3_R                     : 43.75
    haSC200_6_Sensor_4_R                     : 41.81
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 18.92
    haITC502_2_Sensor_2_R                    : 18.93
    haITC502_2_Sensor_3_R                    : 18.97
    haITC502_4_Sensor_1_R                    : 120.5
    haITC502_4_Sensor_2_R                    : 18.9
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 95.43
    haITC502_5_Sensor_2_R                    : 26.45
    haITC502_5_Sensor_3_R                    : 3155.2
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.22
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 110
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF