User name adev
Log entry time 09:33:46 on April 22, 2001
Entry number 61012
keyword=Start_Run_3787_RunType=Other,Tar=9foil-12C,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3787 at Sun Apr 22 09:33:34 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 738.535
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : -0.018497
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 422.783
Right Arm Q2 momentum : 0.982612
Right Arm Q2 gauss meter : 0.2222
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 333.134
Right Arm D1 momentum : 0.982265
Right Arm D1 NMR : 0.364507
Right Arm Q3 power supply current : 390.858
Right Arm Q3 momentum : 0.98228
Right Arm Q3 gauss meter : 0.17511
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 738.64
Left Arm Q1 momentum : 0.981801
Left Arm Q1 gauss meter : -0.06252
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 423.015
Left Arm Q2 momentum : 0.982385
Left Arm Q2 gauss meter : 0.2235
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 327.095
Left Arm D1 momentum : 0.982293
Left Arm D1 NMR : 0.363679
Left Arm Q3 power supply current : 391.006
Left Arm Q3 momentum : 0.982134
Left Arm Q3 gauss meter : -0.19508
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 38.3819
Current on Unser monitor : 45.7433
Current on Upstream bcm : 38.3744
Current on Downstream bcm : 38.4359
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 40.0499
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.166056
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242
haSC200_6_Sensor_2_R : 32.36
haSC200_6_Sensor_3_R : 43.87
haSC200_6_Sensor_4_R : 41.86
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 123.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 96.49
haITC502_5_Sensor_2_R : 26.88
haITC502_5_Sensor_3_R : 10
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.24
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -3562
HacR_VPM_LVDT:VALr : 794
HacR_HPE1313A:0_Ch58 : -0.518066
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.943359
HacR_alignROLL : -0.463812
HacR_alignPITCH : -0.0358297
HacR_alignHPT : 1.194
HacL_HPM_LVDT:VALr : -6785
HacL_VPM_LVDT:VALr : -179
HacL_HPE1313A:0_Ch58 : -0.23291
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.28418
HacL_alignROLL : 0.0801501
HacL_alignPITCH : -0.0370479
HacL_alignHPT : 3.80977
Right Arm Angle Floor Angle : 43.5
Right Arm Angle Vernier : -17
Right Arm Scattering Angle : 43.5909
Left Arm Angle Floor Angle : 43.5
Left Arm Angle Vernier : 48.7
Left Arm Scattering Angle : 43.5759
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 208
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88