    User name adev

    Log entry time 09:59:58 on April 22, 2001

    Entry number 61015

    keyword=End_of_Run_3788
    ****************************
     Run Number: 3788
    End of Run Comment:
    RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White Scan,mode=singles,Lmom=0.9823,Rmom=0.9823,Ene=3994,Angle_R=43.6,Angle_L=43.6
    
    
    Time of run = 16.045784 min
    Av. current (on 3x) = 43.060531 uA
    Av. current (on 1x) = 86.111194 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   82.9033  |   41.4564  |   73.1577
    up-down    (mC)|   -0.8002  |   82.9562  |   -1.8248
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 9887.6125 Hz  |    229621.2 /mC  |  617.976 Hz  |   9519270  |    16   |    114823.8 /mC
        2      | 494.54214 Hz  |     11484.8 /mC  |  494.542 Hz  |    476119  |     1   |      5743.1 /mC
        3      | 9540.4518 Hz  |    221559.1 /mC  |  596.278 Hz  |   9185042  |    16   |    110792.2 /mC
        4      | 588.26458 Hz  |     13661.3 /mC  |  588.265 Hz  |    566350  |     1   |      6831.5 /mC
        5      | 8.6689435 Hz  |       201.3 /mC  |    0.000 Hz  |      8346  | 65535   |       100.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 8.6689435 Hz  |       201.3 /mC  |    0.000 Hz  | 8346.0  | 65535   |       100.7 /mC
        8    | 1024.0 Hz  |     23780.5 /mC  |    0.016 Hz  |    985853  | 65535   |     11891.6 /mC
        output                      1737.632 Hz
    Av. deadtime from accepted triggers = 0.2435
    Av. deadtime from gated scalers = 0.2417
    Accepted triggers  = 1672900.00000
    Rate of Left Arm Pulser for electronic DT  = 0.0
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 0.0
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = -1
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 56788.512
    Rate of Right Arm Strobe  = 47948.812
        Signal     |    Charge   (C)   
       upstream    |    0.0825032     
       upstream 3x |    0.0829345     
       upstream 10x|    0.0722453     
      downstream   |    0.0833034   
     downstream 3x |    -0.0000217   
     downstream 10x|    0.0740701    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3788 at Sun Apr 22 09:59:47 EDT 2001
    Right Arm D1 momentum                    : 0.982299
    Right Arm arm angle                      : 43.591
    Left Arm D1 momentum                      : 0.982301
    Left Arm arm angle                        : 43.5759
    Tiefenbach Hall A energy                : 4000.29
    Right Arm arm mispointing (HPT)          : 1.17591
    Left Arm arm mispointing (HPT)            : 3.80356
    Right Arm Q1 power supply current        : 738.43
    Right Arm Q1 momentum                    : 0.98204
    Right Arm Q1 gauss meter                 : -0.018484
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 422.86
    Right Arm Q2 momentum                    : 0.982555
    Right Arm Q2 gauss meter                 : 0.2223
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 335.059
    Right Arm D1 momentum                    : 0.9823
    Right Arm D1 NMR                         : 0.36452
    Right Arm Q3 power supply current        : 390.869
    Right Arm Q3 momentum                    : 0.982308
    Right Arm Q3 gauss meter                 : 0.17511
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 738.605
    Left Arm Q1 momentum                      : 0.981755
    Left Arm Q1 gauss meter                   : -0.06254
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 422.909
    Left Arm Q2 momentum                      : 0.982138
    Left Arm Q2 gauss meter                   : 0.2235
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 327.112
    Left Arm D1 momentum                      : 0.982302
    Left Arm D1 NMR                           : 0.363683
    Left Arm Q3 power supply current          : 391.088
    Left Arm Q3 momentum                      : 0.98234
    Left Arm Q3 gauss meter                   : -0.19508
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 85.5651
    Current on Unser monitor                : 94.2654
    Current on Upstream bcm                 : 85.4772
    Current on Downstream bcm               : 85.6529
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 87.0005
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2422.92
    Tiefenbach Hall A energy                : 4000.29
    Tiefenbach Hall C energy                : 2418.57
    Delta(E)/E width (MV_AI_DXWID)          : 2.97571
    IPM1C12.XPOS                            : 0.00207973
    IPM1H04A.XPOS                           : 1.14717
    IPM1H04A.YPOS                           : 0.410933
    IPM1H04B.XPOS                           : 1.03786
    IPM1H04B.YPOS                           : -0.0674406
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -3545
     HacR_VPM_LVDT:VALr                     : 786
     HacR_HPE1313A:0_Ch58                   : -0.519043
     HacR_HPE1313A:0_Ch55                   : 22.4609
     HacR_HPE1313A:0_Ch54                   : -0.945312
     HacR_alignROLL                         : -0.465949
     HacR_alignPITCH                        : -0.0347314
     HacR_alignHPT                          : 1.17619
     HacL_HPM_LVDT:VALr                     : -6779
     HacL_VPM_LVDT:VALr                     : -177
     HacL_HPE1313A:0_Ch58                   : -0.233398
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.285645
     HacL_alignROLL                         : 0.079638
     HacL_alignPITCH                        : -0.0361025
     HacL_alignHPT                          : 3.80332
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 68
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 21.42
    haH2_P_Exhaust_R                         : 21.77
    haH2_P_Fill_Bottle_R                     : 21.39
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 19.43
    haD2_P_Fill_Bottle_R                     : 40.02
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.68
    haSC200_6_Sensor_2_R                     : 32.46
    haSC200_6_Sensor_3_R                     : 43.69
    haSC200_6_Sensor_4_R                     : 41.76
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.23
    haITC502_4_Sensor_1_R                    : 124.8
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 97.68
    haITC502_5_Sensor_2_R                    : 96.73
    haITC502_5_Sensor_3_R                    : 264.6
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.22
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 306
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF