User name adev
Log entry time 11:17:06 on April 22, 2001
Entry number 61022
keyword=Start_Run_3792_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3792 at Sun Apr 22 11:16:57 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 800.87
Right Arm Q1 momentum : 1.06508
Right Arm Q1 gauss meter : -0.020028
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 458.15
Right Arm Q2 momentum : 1.06456
Right Arm Q2 gauss meter : 0.2409
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 364.356
Right Arm D1 momentum : 1.065
Right Arm D1 NMR : 0.395208
Right Arm Q3 power supply current : 423.62
Right Arm Q3 momentum : 1.06462
Right Arm Q3 gauss meter : 0.18989
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 801.325
Left Arm Q1 momentum : 1.06512
Left Arm Q1 gauss meter : -0.06781
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 458.619
Left Arm Q2 momentum : 1.06507
Left Arm Q2 gauss meter : 0.2423
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 355.249
Left Arm D1 momentum : 1.065
Left Arm D1 NMR : 0.39428
Left Arm Q3 power supply current : 423.937
Left Arm Q3 momentum : 1.06485
Left Arm Q3 gauss meter : -0.2114
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 84.9721
Current on Unser monitor : 92.3496
Current on Upstream bcm : 84.8758
Current on Downstream bcm : 85.0683
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 148.063
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.61
haSC200_6_Sensor_2_R : 32.88
haSC200_6_Sensor_3_R : 43.72
haSC200_6_Sensor_4_R : 41.81
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 127.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.06
haITC502_5_Sensor_2_R : 0.05
haITC502_5_Sensor_3_R : 982.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.28
Right Arm Arm Collimator : 0.865088
Left Arm Arm Collimator : 0.867969
HacR_HPM_LVDT:VALr : -4660
HacR_VPM_LVDT:VALr : 685
HacR_HPE1313A:0_Ch58 : -0.521973
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.875488
HacR_alignROLL : -0.395516
HacR_alignPITCH : -0.0319715
HacR_alignHPT : 2.38326
HacL_HPM_LVDT:VALr : -8577
HacL_VPM_LVDT:VALr : -658
HacL_HPE1313A:0_Ch58 : -0.285156
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.362305
HacL_alignROLL : 0.0101478
HacL_alignPITCH : 0.00944711
HacL_alignHPT : 5.84456
Right Arm Angle Floor Angle : 46
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 46.3826
Left Arm Angle Floor Angle : 46.5
Left Arm Angle Vernier : 13.5
Left Arm Scattering Angle : 46.3592
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 326
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88