User name adev
Log entry time 13:25:32 on April 22, 2001
Entry number 61030
keyword=Start_Run_3796_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3796 at Sun Apr 22 13:25:14 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 769.09
Right Arm Q1 momentum : 1.02281
Right Arm Q1 gauss meter : -0.019238
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 439.928
Right Arm Q2 momentum : 1.02222
Right Arm Q2 gauss meter : 0.2314
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 347.636
Right Arm D1 momentum : 1.02277
Right Arm D1 NMR : 0.379538
Right Arm Q3 power supply current : 406.952
Right Arm Q3 momentum : 1.02273
Right Arm Q3 gauss meter : 0.18237
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 769.58
Left Arm Q1 momentum : 1.02293
Left Arm Q1 gauss meter : -0.06513
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 440.572
Left Arm Q2 momentum : 1.02316
Left Arm Q2 gauss meter : 0.2328
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 340.79
Left Arm D1 momentum : 1.0228
Left Arm D1 NMR : 0.378667
Left Arm Q3 power supply current : 407.208
Left Arm Q3 momentum : 1.02283
Left Arm Q3 gauss meter : -0.2029
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 86.5872
Current on Unser monitor : 93.1472
Current on Upstream bcm : 86.9119
Current on Downstream bcm : 86.2626
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 148.69
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.03053
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 68.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.66
haSC200_6_Sensor_2_R : 33.4
haSC200_6_Sensor_3_R : 43.72
haSC200_6_Sensor_4_R : 41.81
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 131.7
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.47
haITC502_5_Sensor_2_R : 323.21
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.2
Right Arm Arm Collimator : 0.865771
Left Arm Arm Collimator : 0.868555
HacR_HPM_LVDT:VALr : -4672
HacR_VPM_LVDT:VALr : 674
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.881348
HacR_alignROLL : -0.399896
HacR_alignPITCH : -0.0320383
HacR_alignHPT : 2.39796
HacL_HPM_LVDT:VALr : -8567
HacL_VPM_LVDT:VALr : -662
HacL_HPE1313A:0_Ch58 : -0.283203
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.359863
HacL_alignROLL : 0.0106581
HacL_alignPITCH : 0.00850295
HacL_alignHPT : 5.83314
Right Arm Angle Floor Angle : 46
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 46.3825
Left Arm Angle Floor Angle : 46.5
Left Arm Angle Vernier : 13.5
Left Arm Scattering Angle : 46.3593
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 331
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88