    User name adev

    Log entry time 13:42:40 on April 22, 2001

    Entry number 61031

    keyword=End_of_Run_3796
    ****************************
     Run Number: 3796
    End of Run Comment:
    RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White Scan,mode=singles,Lmom=1.0228,Rmom=1.0228,Ene=3994,Angle_R=46.38,Angle_L=46.36. Open collimator.
    
    
    Time of run = 17.082405 min
    Av. current (on 3x) = 43.041754 uA
    Av. current (on 1x) = 86.071507 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   88.2185  |   44.1154  |   77.8752
    up-down    (mC)|   -0.8533  |   88.2770  |   -1.9409
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 8353.8705 Hz  |    194087.6 /mC  |  522.117 Hz  |   8562252  |    16   |     97057.3 /mC
        2      | 492.47554 Hz  |     11441.8 /mC  |  492.476 Hz  |    504760  |     1   |      5721.7 /mC
        3      | 8126.8533 Hz  |    188813.2 /mC  |  507.928 Hz  |   8329572  |    16   |     94419.8 /mC
        4      | 561.09 Hz  |     13035.9 /mC  |  561.090 Hz  |    575086  |     1   |      6518.9 /mC
        5      | 6.1632617 Hz  |       143.2 /mC  |    0.000 Hz  |      6317  | 65535   |        71.6 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 6.1632617 Hz  |       143.2 /mC  |    0.000 Hz  | 6317.0  | 65535   |        71.6 /mC
        8    | 1024.0 Hz  |     23790.9 /mC  |    0.016 Hz  |   1049543  | 65535   |     11897.1 /mC
        output                      1584.516 Hz
    Av. deadtime from accepted triggers = 0.2395
    Av. deadtime from gated scalers = 0.2307
    Accepted triggers  = 1624041.00000
    Rate of Left Arm Pulser for electronic DT  = 0.0
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 0.0
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = -1
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 56626.054
    Rate of Right Arm Strobe  = 46797.253
        Signal     |    Charge   (C)   
       upstream    |    0.0877918     
       upstream 3x |    0.0882539     
       upstream 10x|    0.0769048     
      downstream   |    0.0886451   
     downstream 3x |    -0.0000231   
     downstream 10x|    0.0788457    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3796 at Sun Apr 22 13:42:29 EDT 2001
    Right Arm D1 momentum                    : 1.0228
    Right Arm arm angle                      : 46.3825
    Left Arm D1 momentum                      : 1.0228
    Left Arm arm angle                        : 46.3593
    Tiefenbach Hall A energy                : 4000.35
    Right Arm arm mispointing (HPT)          : 2.39883
    Left Arm arm mispointing (HPT)            : 5.83365
    Right Arm Q1 power supply current        : 769.09
    Right Arm Q1 momentum                    : 1.02281
    Right Arm Q1 gauss meter                 : -0.019242
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 440.273
    Right Arm Q2 momentum                    : 1.02302
    Right Arm Q2 gauss meter                 : 0.2314
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 349.252
    Right Arm D1 momentum                    : 1.0228
    Right Arm D1 NMR                         : 0.37955
    Right Arm Q3 power supply current        : 406.98
    Right Arm Q3 momentum                    : 1.0228
    Right Arm Q3 gauss meter                 : 0.18235
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 769.58
    Left Arm Q1 momentum                      : 1.02293
    Left Arm Q1 gauss meter                   : -0.06514
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 440.491
    Left Arm Q2 momentum                      : 1.02297
    Left Arm Q2 gauss meter                   : 0.2328
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 340.789
    Left Arm D1 momentum                      : 1.0228
    Left Arm D1 NMR                           : 0.378667
    Left Arm Q3 power supply current          : 407.175
    Left Arm Q3 momentum                      : 1.02275
    Left Arm Q3 gauss meter                   : -0.2029
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 86.2542
    Current on Unser monitor                : 92.5695
    Current on Upstream bcm                 : 86.1969
    Current on Downstream bcm               : 86.3115
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 147.398
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2422.92
    Tiefenbach Hall A energy                : 4000.35
    Tiefenbach Hall C energy                : 2418.53
    Delta(E)/E width (MV_AI_DXWID)          : 2.98978
    IPM1C12.XPOS                            : 0.00105858
    IPM1H04A.XPOS                           : 1.07355
    IPM1H04A.YPOS                           : 0.440359
    IPM1H04B.XPOS                           : 0.984287
    IPM1H04B.YPOS                           : -0.0262201
    Right Arm Arm Collimator                 : 0.838916
    Left Arm Arm Collimator                   : 0.85293
     HacR_HPM_LVDT:VALr                     : -4672
     HacR_VPM_LVDT:VALr                     : 681
     HacR_HPE1313A:0_Ch58                   : -0.521973
     HacR_HPE1313A:0_Ch55                   : 22.4121
     HacR_HPE1313A:0_Ch54                   : -0.878906
     HacR_alignROLL                         : -0.399953
     HacR_alignPITCH                        : -0.0328692
     HacR_alignHPT                          : 2.398
     HacL_HPM_LVDT:VALr                     : -8568
     HacL_VPM_LVDT:VALr                     : -664
     HacL_HPE1313A:0_Ch58                   : -0.283691
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.359863
     HacL_alignROLL                         : 0.0119146
     HacL_alignPITCH                        : 0.00901052
     HacL_alignHPT                          : 5.83477
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 68.5
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 22.07
    haH2_P_Exhaust_R                         : 22.37
    haH2_P_Fill_Bottle_R                     : 22.04
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 19.76
    haD2_P_Fill_Bottle_R                     : 40.68
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 241.68
    haSC200_6_Sensor_2_R                     : 33.47
    haSC200_6_Sensor_3_R                     : 43.74
    haSC200_6_Sensor_4_R                     : 41.84
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.24
    haITC502_4_Sensor_1_R                    : 132.2
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 3.99
    haITC502_5_Sensor_2_R                    : 1
    haITC502_5_Sensor_3_R                    : 0.6
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.19
    Right Arm Arm Collimator                 : 0.822852
    Left Arm Arm Collimator                   : 0.840527
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 331
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF