User name adev
Log entry time 13:46:35 on April 22, 2001
Entry number 61032
keyword=Start_Run_3797_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3797 at Sun Apr 22 13:46:22 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 769.09
Right Arm Q1 momentum : 1.02281
Right Arm Q1 gauss meter : -0.01924
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 440.383
Right Arm Q2 momentum : 1.02327
Right Arm Q2 gauss meter : 0.2314
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 349.244
Right Arm D1 momentum : 1.0228
Right Arm D1 NMR : 0.379548
Right Arm Q3 power supply current : 406.953
Right Arm Q3 momentum : 1.02273
Right Arm Q3 gauss meter : 0.18232
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 769.615
Left Arm Q1 momentum : 1.02297
Left Arm Q1 gauss meter : -0.0651
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 440.272
Left Arm Q2 momentum : 1.02246
Left Arm Q2 gauss meter : 0.2327
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 340.788
Left Arm D1 momentum : 1.0228
Left Arm D1 NMR : 0.378667
Left Arm Q3 power supply current : 407.198
Left Arm Q3 momentum : 1.02281
Left Arm Q3 gauss meter : -0.2029
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 86.6589
Current on Unser monitor : 92.9794
Current on Upstream bcm : 86.5511
Current on Downstream bcm : 86.7667
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 148.526
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.73
haSC200_6_Sensor_2_R : 33.47
haSC200_6_Sensor_3_R : 43.77
haSC200_6_Sensor_4_R : 41.84
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 132.3
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.05
haITC502_5_Sensor_2_R : 98.58
haITC502_5_Sensor_3_R : 976.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.19
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4696
HacR_VPM_LVDT:VALr : 675
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.879883
HacR_alignROLL : -0.399953
HacR_alignPITCH : -0.0324203
HacR_alignHPT : 2.42575
HacL_HPM_LVDT:VALr : -8571
HacL_VPM_LVDT:VALr : -667
HacL_HPE1313A:0_Ch58 : -0.283691
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.359863
HacL_alignROLL :
HacL_alignPITCH : 0.00901052
HacL_alignHPT : 5.83812
Right Arm Angle Floor Angle : 46
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 46.3823
Left Arm Angle Floor Angle : 46.5
Left Arm Angle Vernier : 13.5
Left Arm Scattering Angle : 46.3593
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 332
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88