Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 14:16:07 on April 22, 2001
Entry number 61034
keyword=Start_Run_3798_RunType=Other,Tar=9foil-12C,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3798 at Sun Apr 22 14:15:58 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 769.125
Right Arm Q1 momentum : 1.02286
Right Arm Q1 gauss meter : -0.019238
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 440.14
Right Arm Q2 momentum : 1.02271
Right Arm Q2 gauss meter : 0.2315
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 349.253
Right Arm D1 momentum : 1.0228
Right Arm D1 NMR : 0.379549
Right Arm Q3 power supply current : 407.144
Right Arm Q3 momentum : 1.02321
Right Arm Q3 gauss meter : 0.18239
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 769.51
Left Arm Q1 momentum : 1.02283
Left Arm Q1 gauss meter : -0.06512
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 440.187
Left Arm Q2 momentum : 1.02226
Left Arm Q2 gauss meter : 0.2327
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 340.786
Left Arm D1 momentum : 1.0228
Left Arm D1 NMR : 0.378667
Left Arm Q3 power supply current : 407.206
Left Arm Q3 momentum : 1.02283
Left Arm Q3 gauss meter : -0.2029
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 38.3941
Current on Unser monitor : 45.9709
Current on Upstream bcm : 38.1612
Current on Downstream bcm : 38.627
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 100.643
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.166056
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.98
haSC200_6_Sensor_2_R : 33.7
haSC200_6_Sensor_3_R : 43.94
haSC200_6_Sensor_4_R : 41.92
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 133.2
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 323.22
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 985.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.12
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4722
HacR_VPM_LVDT:VALr : 661
HacR_HPE1313A:0_Ch58 : -0.520508
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.880859
HacR_alignROLL : -0.400389
HacR_alignPITCH : -0.0333848
HacR_alignHPT : 2.45486
HacL_HPM_LVDT:VALr : -8569
HacL_VPM_LVDT:VALr : -660
HacL_HPE1313A:0_Ch58 : -0.282715
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.36084
HacL_alignROLL : 0.011306
HacL_alignPITCH : 0.00785299
HacL_alignHPT : 5.83618
Right Arm Angle Floor Angle : 46
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 46.3821
Left Arm Angle Floor Angle : 46.5
Left Arm Angle Vernier : 13.5
Left Arm Scattering Angle : 46.3593
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 209
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88