User name adev
Log entry time 19:24:46 on April 22, 2001
Entry number 61059
keyword=Start_Run_3808_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3808 at Sun Apr 22 19:24:32 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 784.945
Right Arm Q1 momentum : 1.0439
Right Arm Q1 gauss meter : -0.019626
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 449.162
Right Arm Q2 momentum : 1.04367
Right Arm Q2 gauss meter : 0.2362
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 356.705
Right Arm D1 momentum : 1.0437
Right Arm D1 NMR : 0.387304
Right Arm Q3 power supply current : 415.296
Right Arm Q3 momentum : 1.0437
Right Arm Q3 gauss meter : 0.18606
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 785.365
Left Arm Q1 momentum : 1.04391
Left Arm Q1 gauss meter : -0.06645
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 449.368
Left Arm Q2 momentum : 0
Left Arm Q2 gauss meter : 0.2375
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 347.977
Left Arm D1 momentum : 1.0437
Left Arm D1 NMR : 0.3864
Left Arm Q3 power supply current : 415.517
Left Arm Q3 momentum : 1.0437
Left Arm Q3 gauss meter : -0.207
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 86.5696
Current on Unser monitor : 93.3775
Current on Upstream bcm : 86.8133
Current on Downstream bcm : 86.3259
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 150.023
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.64
haSC200_6_Sensor_2_R : 34.32
haSC200_6_Sensor_3_R : 43.69
haSC200_6_Sensor_4_R : 41.82
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 140.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 264.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.19
Right Arm Arm Collimator : 0.86543
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -4377
HacR_VPM_LVDT:VALr : 689
HacR_HPE1313A:0_Ch58 : -0.522461
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.898926
HacR_alignROLL : -0.418247
HacR_alignPITCH : -0.0314559
HacR_alignHPT : 2.08088
HacL_HPM_LVDT:VALr : -6901
HacL_VPM_LVDT:VALr : -431
HacL_HPE1313A:0_Ch58 : -0.265137
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.339844
HacL_alignROLL : 0.0304667
HacL_alignPITCH : -0.00801645
HacL_alignHPT : 3.96212
Right Arm Angle Floor Angle : 45.5
Right Arm Angle Vernier : 1
Right Arm Scattering Angle : 45.6887
Left Arm Angle Floor Angle : 45.5
Left Arm Angle Vernier : 67
Left Arm Scattering Angle : 45.6803
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 338
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88