Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 20:39:10 on April 22, 2001
Entry number 61066
keyword=Start_Run_3811_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3811 at Sun Apr 22 20:38:49 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 753.655
Right Arm Q1 momentum : 1.00229
Right Arm Q1 gauss meter : -0.01887
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 431.567
Right Arm Q2 momentum : 1.00279
Right Arm Q2 gauss meter : 0.2268
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 340.346
Right Arm D1 momentum : 1.00226
Right Arm D1 NMR : 0.371928
Right Arm Q3 power supply current : 398.871
Right Arm Q3 momentum : 1.00242
Right Arm Q3 gauss meter : 0.1788
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 754.145
Left Arm Q1 momentum : 1.00241
Left Arm Q1 gauss meter : -0.06384
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 431.65
Left Arm Q2 momentum : 1.00244
Left Arm Q2 gauss meter : 0.228
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 333.816
Left Arm D1 momentum : 1.00229
Left Arm D1 NMR : 0.371079
Left Arm Q3 power supply current : 399.045
Left Arm Q3 momentum : 1.00233
Left Arm Q3 gauss meter : -0.1991
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 86.8331
Current on Unser monitor : 93.9631
Current on Upstream bcm : 86.7116
Current on Downstream bcm : 86.9547
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 150.403
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 71.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.64
haSC200_6_Sensor_2_R : 34.47
haSC200_6_Sensor_3_R : 43.7
haSC200_6_Sensor_4_R : 41.86
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 141.8
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 315.5
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 963.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.23
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4397
HacR_VPM_LVDT:VALr : 683
HacR_HPE1313A:0_Ch58 : -0.522461
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.898438
HacR_alignROLL : -0.419233
HacR_alignPITCH : -0.0314559
HacR_alignHPT : 2.10326
HacL_HPM_LVDT:VALr : -6904
HacL_VPM_LVDT:VALr : -441
HacL_HPE1313A:0_Ch58 : -0.265137
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.339355
HacL_alignROLL : 0.0305358
HacL_alignPITCH : -0.00808787
HacL_alignHPT : 3.96544
Right Arm Angle Floor Angle : 45.5
Right Arm Angle Vernier : 1
Right Arm Scattering Angle : 45.6885
Left Arm Angle Floor Angle : 45.5
Left Arm Angle Vernier : 67
Left Arm Scattering Angle : 45.6803
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 337
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88