User name adev
Log entry time 22:08:51 on April 22, 2001
Entry number 61070
keyword=Start_Run_3813_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3813 at Sun Apr 22 22:08:39 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 800.8
Right Arm Q1 momentum : 1.06499
Right Arm Q1 gauss meter : -0.020032
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 458.492
Right Arm Q2 momentum : 1.06535
Right Arm Q2 gauss meter : 0.241
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 364.418
Right Arm D1 momentum : 1.065
Right Arm D1 NMR : 0.395209
Right Arm Q3 power supply current : 423.673
Right Arm Q3 momentum : 1.06475
Right Arm Q3 gauss meter : 0.18988
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 801.5
Left Arm Q1 momentum : 1.06535
Left Arm Q1 gauss meter : -0.06779
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 458.552
Left Arm Q2 momentum : 1.06491
Left Arm Q2 gauss meter : 0.2424
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 355.278
Left Arm D1 momentum : 1.06501
Left Arm D1 NMR : 0.394284
Left Arm Q3 power supply current : 423.918
Left Arm Q3 momentum : 1.0648
Left Arm Q3 gauss meter : -0.2114
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0600128
Current on Unser monitor : 7.31964
Current on Upstream bcm : 0.0612926
Current on Downstream bcm : 0.0587331
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02808
Radiator Encoder : 0.166056
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.86
haSC200_6_Sensor_2_R : 34.76
haSC200_6_Sensor_3_R : 43.84
haSC200_6_Sensor_4_R : 41.97
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 143.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.49
haITC502_5_Sensor_2_R : 312.02
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.19
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : Inf
HacR_VPM_LVDT:VALr : 773
HacR_HPE1313A:0_Ch58 : -0.52002
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.939941
HacR_alignROLL : -0.460527
HacR_alignPITCH : -0.0342825
HacR_alignHPT : -0.226121
HacL_HPM_LVDT:VALr : -6714
HacL_VPM_LVDT:VALr : -184
HacL_HPE1313A:0_Ch58 : -0.234863
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.274902
HacL_alignROLL : 0.0889145
HacL_alignPITCH : -0.0347926
HacL_alignHPT : 3.72623
Right Arm Angle Floor Angle : 44
Right Arm Angle Vernier : 18
Right Arm Scattering Angle : 44.3023
Left Arm Angle Floor Angle : 44.5
Left Arm Angle Vernier : -3.8
Left Arm Scattering Angle : 44.2739
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 110
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88