User name adev
Log entry time 23:23:45 on April 22, 2001
Entry number 61074
keyword=Start_Run_3815_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3815 at Sun Apr 22 23:23:31 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 784.735
Right Arm Q1 momentum : 1.04362
Right Arm Q1 gauss meter : -0.019631
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 449.158
Right Arm Q2 momentum : 1.04366
Right Arm Q2 gauss meter : 0.2361
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 356.615
Right Arm D1 momentum : 1.0437
Right Arm D1 NMR : 0.387305
Right Arm Q3 power supply current : 415.253
Right Arm Q3 momentum : 1.04359
Right Arm Q3 gauss meter : 0.18605
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 785.365
Left Arm Q1 momentum : 1.04391
Left Arm Q1 gauss meter : -0.06647
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 449.397
Left Arm Q2 momentum : 1.04365
Left Arm Q2 gauss meter : 0.2375
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 347.984
Left Arm D1 momentum : 1.04371
Left Arm D1 NMR : 0.386401
Left Arm Q3 power supply current : 415.518
Left Arm Q3 momentum : 1.0436
Left Arm Q3 gauss meter : -0.207
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 86.6074
Current on Unser monitor : 94.8936
Current on Upstream bcm : 86.7185
Current on Downstream bcm : 86.4963
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 150.028
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.36
haSC200_6_Sensor_2_R : 34.96
haSC200_6_Sensor_3_R : 44.07
haSC200_6_Sensor_4_R : 42.11
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 144.5
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 309.06
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.23
Right Arm Arm Collimator : 0.86543
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -2282
HacR_VPM_LVDT:VALr : 767
HacR_HPE1313A:0_Ch58 : -0.518555
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.938477
HacR_alignROLL : -0.458938
HacR_alignPITCH : -0.0353139
HacR_alignHPT : -0.241579
HacL_HPM_LVDT:VALr : -6719
HacL_VPM_LVDT:VALr : -197
HacL_HPE1313A:0_Ch58 : -0.233398
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.276367
HacL_alignROLL : 0.088384
HacL_alignPITCH : -0.0364635
HacL_alignHPT : 3.73319
Right Arm Angle Floor Angle : 44
Right Arm Angle Vernier : 18
Right Arm Scattering Angle : 44.3024
Left Arm Angle Floor Angle : 44.5
Left Arm Angle Vernier : -3.8
Left Arm Scattering Angle : 44.2738
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 338
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88