Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:45:46 on April 23, 2001
Entry number 61087
keyword=Start_Run_3820_RunType=Other,Tar=9foil-12C,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3820 at Mon Apr 23 01:45:33 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 769.02
Right Arm Q1 momentum : 1.02272
Right Arm Q1 gauss meter : -0.019237
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 440.326
Right Arm Q2 momentum : 1.02314
Right Arm Q2 gauss meter : 0.2315
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 349.291
Right Arm D1 momentum : 1.0228
Right Arm D1 NMR : 0.379549
Right Arm Q3 power supply current : 406.748
Right Arm Q3 momentum : 1.02221
Right Arm Q3 gauss meter :
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 769.125
Left Arm Q1 momentum : 1.02232
Left Arm Q1 gauss meter : -0.06509
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 440.426
Left Arm Q2 momentum : 1.02337
Left Arm Q2 gauss meter : 0.2328
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 340.812
Left Arm D1 momentum : 1.02281
Left Arm D1 NMR : 0.378668
Left Arm Q3 power supply current : 407.217
Left Arm Q3 momentum : 1.02285
Left Arm Q3 gauss meter : -0.2029
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 78.6594
Current on Unser monitor : 87.5819
Current on Upstream bcm : 79.4853
Current on Downstream bcm : 80.347
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 142.178
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.163614
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 35.06
haSC200_6_Sensor_3_R : 44.12
haSC200_6_Sensor_4_R : 42.06
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 146.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 92.18
haITC502_5_Sensor_2_R : 26.68
haITC502_5_Sensor_3_R : 3043
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.15
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -2306
HacR_VPM_LVDT:VALr : 742
HacR_HPE1313A:0_Ch58 : -0.518066
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.938965
HacR_alignROLL : -0.458883
HacR_alignPITCH : -0.0358297
HacR_alignHPT : -0.215864
HacL_HPM_LVDT:VALr : -6714
HacL_VPM_LVDT:VALr : -210
HacL_HPE1313A:0_Ch58 : -0.233398
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.276855
HacL_alignROLL : 0.087571
HacL_alignPITCH : -0.0365357
HacL_alignHPT : 3.72688
Right Arm Angle Floor Angle : 44
Right Arm Angle Vernier : 18
Right Arm Scattering Angle : 44.3022
Left Arm Angle Floor Angle : 44.5
Left Arm Angle Vernier : -3.8
Left Arm Scattering Angle : 44.2739
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 323
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88