User name adev
Log entry time 02:50:10 on April 23, 2001
Entry number 61091
keyword=Start_Run_3822_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3822 at Mon Apr 23 02:50:00 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 753.69
Right Arm Q1 momentum : 1.00219
Right Arm Q1 gauss meter : -0.018856
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 431.292
Right Arm Q2 momentum : 1.00215
Right Arm Q2 gauss meter : 0.2268
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.071
Right Arm D1 momentum : 1.0023
Right Arm D1 NMR : 0.371942
Right Arm Q3 power supply current : 398.845
Right Arm Q3 momentum : 1.00235
Right Arm Q3 gauss meter : 0.17879
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 753.76
Left Arm Q1 momentum : 1.0019
Left Arm Q1 gauss meter : -0.06377
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 431.603
Left Arm Q2 momentum : 1.00233
Left Arm Q2 gauss meter : 0.228
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 333.807
Left Arm D1 momentum : 1.00229
Left Arm D1 NMR : 0.371077
Left Arm Q3 power supply current : 399.071
Left Arm Q3 momentum : 1.00239
Left Arm Q3 gauss meter : -0.19909
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 84.1902
Current on Unser monitor : 91.0867
Current on Upstream bcm : 84.1336
Current on Downstream bcm : 84.2467
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 129.246
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.156288
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.55
haSC200_6_Sensor_2_R : 35.16
haSC200_6_Sensor_3_R : 44.19
haSC200_6_Sensor_4_R : 42.11
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 147.2
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.05
haITC502_5_Sensor_2_R : 92.84
haITC502_5_Sensor_3_R : 919.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.26
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -2274
HacR_VPM_LVDT:VALr : 756
HacR_HPE1313A:0_Ch58 : -0.517578
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.938477
HacR_alignROLL : -0.458883
HacR_alignPITCH : -0.0362786
HacR_alignHPT : -0.250565
HacL_HPM_LVDT:VALr : -6715
HacL_VPM_LVDT:VALr : -217
HacL_HPE1313A:0_Ch58 : -0.233398
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.276855
HacL_alignROLL : 0.0876416
HacL_alignPITCH : -0.036608
HacL_alignHPT : 3.728
Right Arm Angle Floor Angle : 44
Right Arm Angle Vernier : 18
Right Arm Scattering Angle : 44.3024
Left Arm Angle Floor Angle : 44.5
Left Arm Angle Vernier : -3.8
Left Arm Scattering Angle : 44.2738
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 330
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88