User name adev
Log entry time 03:07:16 on April 23, 2001
Entry number 61092
keyword=End_of_Run_3822
****************************
Run Number: 3822
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White Scan,mode=singles,Lmom=1.0023,Rmom=1.0023,Ene=3994,Angle_R=44.3,Angle_L=44.3
Time of run = 17.119075 min
Av. current (on 3x) = 24.337472 uA
Av. current (on 1x) = 48.67689 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 49.9982 | 24.9981 | 44.3993
up-down (mC)| -0.4779 | 50.0426 | -1.0789
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 7185.102 Hz | 295228.0 /mC | 449.069 Hz | 7380138 | 16 | 147608.1 /mC
2 | 397.49909 Hz | 16332.8 /mC | 397.499 Hz | 408289 | 1 | 8166.1 /mC
3 | 7251.4578 Hz | 297954.4 /mC | 453.216 Hz | 7448295 | 16 | 148971.3 /mC
4 | 476.79465 Hz | 19591.0 /mC | 476.795 Hz | 489737 | 1 | 9795.1 /mC
5 | 18.37424 Hz | 755.0 /mC | 0.000 Hz | 18873 | 65535 | 377.5 /mC
Trigger 5 corrected for pulser:
5 (phys) | 8.205272 Hz | 337.1 /mC | 0.000 Hz | 8428.0004 | 65535 | 168.6 /mC
8 | 1024.0 Hz | 42075.0 /mC | 0.016 Hz | 1051796 | 65535 | 21036.7 /mC
output 1250.899 Hz
Av. deadtime from accepted triggers = 0.2959
Av. deadtime from gated scalers = 0.2946
Accepted triggers = 1284854.00000
Rate of Left Arm Pulser for electronic DT = 10.168968
Rate of Right Arm Pulser for electronic DT = 10.185519
Rate of Left Arm Pulser&trig for electronic DT = 10.166048
Rate of Right Arm Pulser&trig for electronic DT = 10.185519
Left Arm Electronic DT = 0.00028721876
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 38132.973
Rate of Right Arm Strobe = 31705.12
Signal | Charge (C)
upstream | 0.0497593
upstream 3x | 0.0500194
upstream 10x| 0.0438598
downstream | 0.0502372
downstream 3x | -0.0000232
downstream 10x| 0.0449387
****************************
End-of-run EPICS data for Run Number 3822 at Mon Apr 23 03:07:05 EDT 2001
Right Arm D1 momentum : 1.0023
Right Arm arm angle : 44.3025
Left Arm D1 momentum : 1.00228
Left Arm arm angle : 44.2739
Tiefenbach Hall A energy : 4000.29
Right Arm arm mispointing (HPT) : -0.262254
Left Arm arm mispointing (HPT) : 3.71668
Right Arm Q1 power supply current : 753.655
Right Arm Q1 momentum : 1.00229
Right Arm Q1 gauss meter : -0.018865
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 431.325
Right Arm Q2 momentum : 1.00223
Right Arm Q2 gauss meter : 0.2268
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.07
Right Arm D1 momentum : 1.0023
Right Arm D1 NMR : 0.371941
Right Arm Q3 power supply current : 398.815
Right Arm Q3 momentum : 1.00228
Right Arm Q3 gauss meter : 0.17878
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 753.655
Left Arm Q1 momentum : 1.00176
Left Arm Q1 gauss meter : -0.0638
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 431.555
Left Arm Q2 momentum : 1.00222
Left Arm Q2 gauss meter : 0.2281
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 333.809
Left Arm D1 momentum : 1.00229
Left Arm D1 NMR : 0.371076
Left Arm Q3 power supply current : 399.034
Left Arm Q3 momentum : 1.0023
Left Arm Q3 gauss meter : -0.1991
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0611541
Current on Unser monitor : 6.54722
Current on Upstream bcm : 0.0628167
Current on Downstream bcm : 0.0594914
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
MBSY1c Bdl : 1.00019e+06
MBSY3c Hall C Beam energy : 2423.72
Tiefenbach Hall A energy : 4000.29
Tiefenbach Hall C energy : 2417.93
Delta(E)/E width (MV_AI_DXWID) : 2.98362
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868555
HacR_HPM_LVDT:VALr : -2262
HacR_VPM_LVDT:VALr : 754
HacR_HPE1313A:0_Ch58 : -0.519043
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.938965
HacR_alignROLL : -0.460417
HacR_alignPITCH : -0.0353139
HacR_alignHPT : -0.263123
HacL_HPM_LVDT:VALr : -6706
HacL_VPM_LVDT:VALr : -204
HacL_HPE1313A:0_Ch58 : -0.234375
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.276855
HacL_alignROLL : 0.0874299
HacL_alignPITCH : -0.0359547
HacL_alignHPT : 3.71689
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 20.48
haH2_P_Exhaust_R : 20.86
haH2_P_Fill_Bottle_R : 20.52
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.83
haD2_P_Fill_Bottle_R : 38.91
haD2_DP_Fill_Exhaust_R : 0.0742
haSC200_6_Sensor_1_R : 242.15
haSC200_6_Sensor_2_R : 34.99
haSC200_6_Sensor_3_R : 43.95
haSC200_6_Sensor_4_R : 41.99
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.02
haITC502_4_Sensor_1_R : 147.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 91.91
haITC502_5_Sensor_2_R : 26.51
haITC502_5_Sensor_3_R : 3033.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.26
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868555
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 110
Laser power Hall A : 57
Half-wave plate (off=out) : OFF