Log entry time 05:49:49 on April 23, 2001
Entry number 61093
keyword=Start_Run_3823_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3823 at Mon Apr 23 05:49:34 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 753.69
Right Arm Q1 momentum : 1.00233
Right Arm Q1 gauss meter : -0.018872
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 431.232
Right Arm Q2 momentum : 1.00201
Right Arm Q2 gauss meter : 0.2268
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 342.069
Right Arm D1 momentum : 1.0023
Right Arm D1 NMR : 0.371941
Right Arm Q3 power supply current : 398.735
Right Arm Q3 momentum : 1.00208
Right Arm Q3 gauss meter : 0.17873
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 753.655
Left Arm Q1 momentum : 1.00176
Left Arm Q1 gauss meter : -0.06381
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 431.533
Left Arm Q2 momentum : 1.00217
Left Arm Q2 gauss meter : 0.228
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 333.818
Left Arm D1 momentum : 1.00231
Left Arm D1 NMR : 0.371084
Left Arm Q3 power supply current : 399.01
Left Arm Q3 momentum : 1.00224
Left Arm Q3 gauss meter : -0.19908
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 84.6476
Current on Unser monitor : 91.8409
Current on Upstream bcm : 84.6039
Current on Downstream bcm : 85.0272
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 85.3782
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.2
haSC200_6_Sensor_2_R : 35.23
haSC200_6_Sensor_3_R : 43.97
haSC200_6_Sensor_4_R : 42.09
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 149.1
haITC502_4_Sensor_2_R : 19.3
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 91.65
haITC502_5_Sensor_3_R : 908.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.24
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868555
HacR_HPM_LVDT:VALr : -2264
HacR_VPM_LVDT:VALr : 795
HacR_HPE1313A:0_Ch58 : -0.519043
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.939453
HacR_alignROLL : -0.460089
HacR_alignPITCH : -0.0342157
HacR_alignHPT : -0.262191
HacL_HPM_LVDT:VALr : -6715
HacL_VPM_LVDT:VALr : -197
HacL_HPE1313A:0_Ch58 : -0.234863
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.274902
HacL_alignROLL : 0.0891263
HacL_alignPITCH : -0.0350091
HacL_alignHPT : 3.72725
Right Arm Angle Floor Angle : 44
Right Arm Angle Vernier : 18
Right Arm Scattering Angle : 44.3025
Left Arm Angle Floor Angle : 44.5
Left Arm Angle Vernier : -3.8
Left Arm Scattering Angle : 44.2738
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 307
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88